18. TANK CLEANING
WARNING! TURN OFF POWER SUPPLY TO THE CABINET BY DISCONNECTING THE POWER
PLUG BEFORE CLEANING.
By tank cleaning, proceed as follows:
1.
Place the goods in special refrigerated containers, kept at the same temperature and remove the shelves.
2.
Before cleaning the tank the inside temperature must be equal to the ambient temperatur.
3.
Leave the doors open and begin the operation of tank washing when the tank temperature is the same as the ambient temperature.
4.
Proceed with washing and drying the internal chamber with a cloth using neutral PH detergent and fresh water.
5.
Clean the surfaces with a cloth, using neutral PH detergent, rinse and dry.
6.
Clean the height adjusters supporting the levels with a jet of air.
7.
Avoid water entering into the appliance lighting units.
8.
Then plug the unit and wait till the appliance reaches the right temperature before filling it again.
Do not use any aggressive or abrasive cleaning agents.
Never use a water hose or a high-pressure jet to clean the cabinet.
WARNING! Do not use jet of water to clean the cabinet: electrical wiring could be damaged.
WARNING! Never use mechanical devices or any other means to accelerate the defrosting process,
other than those recommended by the manufacturer.
19. MAINTENANCE
WARNING! Maintenance must be carried out by technical staff trained and enabled for intervention
on the flammable refrigerants.
WARNING! Any work carried out on the appliance by the user strictly requires the power plug being
disconnected from the mains socket.
ATTENTION! Use protective shoes and gloves during maintenance operations.
OPERATION
Cleaning the outer surface
Cleaning the accessible inner parts (do not use tools)
Checking the power supply, electrical plugs and/or sockets
Seals intactness check
Check the acceptable condition of warning plates
Water collection tank cleaning
Fridge system tubing intactness check
Inspecting the cables and inner power connections
Replacing the led lights
Replacing the power supply cable
Control panel replacement (electronic control unit)
Any other maintenance operation not planned in the previous points should be carried out by the
support centres authorised by our dealers or by qualified staff.
20. TEMPERATURE SETTING AND CONTROLS
Each refrigerating appliance is provided with an electronic control for automatic maintenance of the appropriate pre-established
temperature inside the tank.
Only if the average internal temperature is too cold or not cold you can increment or decrement the temperature:
•
Press the (Set) (2 sec.) key in order to see on display the temperature set point.
•
Press the () key or the () key in order to increment or decrement the temperature set point.
•
Press the (Set ) key in order to store the new temperature set point.
1
2
3
TWIST NEXT
EPTA S.p.A. - Sede legale
Via Mecenate, 86 - 20138 Milano – Italy
Capitale € 68.515.000 - R.E.A./MI – 1730229
Registro delle Imprese e Cod.Fiscale n. 04160730968
Partita IVA 04160730968
This temperature adjuster is gauged by the factory and should not be touched by the user.
FREQUENCY
MAINTENANCE
Based on use
Ordinary
Based on use
Ordinary
Six-monthly
Ordinary
Six-monthly
Ordinary
Six-monthly
Ordinary
Based on use
Ordinary
Six-monthly
Ordinary
Six-monthly
Ordinary
-
Extraordinary
-
Extraordinary
-
Extraordinary
4
1. Light switch
2. Automatic defrosting button (press for defrosting start)
5
3. Button to show set temperature
4. Button to decrease temperature
5. Button to increase temperature
2 1 / 6 0