Further safety instructions:
•
For installation and operation, the national regulations
and safety codes in force must also be adhered to.
•
Do not use the ENL 10 Service-Unit in hazardous areas.
•
Regarding the inlet screw joints, excessive tightening
forces must be avoided. This applies in particular to
conical screw joints.
•
The ENL 10 Service-Unit will only function when
voltage is applied.
•
Do not use the test button for permanent drainage.
•
Use genuine spare parts only. This is imperative to
ensure perfect functioning.
Additional advice:
•
During installation, use the spanner flat at the feed
pipe (wrench size SW28 + 34) as a back rest.
•
The Service-Unit must not be dismantled.
min./max. operating pressure
(see type plate)
min./max. temperature
(see type plate)
Condensate inflow
Condensate outflow
Condensate
Housing
Weight (empty)
4
2. SAFETy INSTRUCTIONS
malfunction during operation!
Through incorrect installation and poor maintenance,
malfunction may occur at the ENL 10 Service-Unit .
Condensate which is not discharged may cause damage
to plants and in production processes.
measures:
•
•
3. TEChNICAL dATA
0,8...16 bar (12...230 psi) or 1,2...16 bar (17...230 psi)
+1...+60 °C (+34...+140 °F) or +1...+70 °C (+34...+158 °F)
Inlet via condensate receiver tank
G ½ (½") Ø 13 mm hose connector
oil-contaminated + oil-free
aluminium + plastic, glass fibre-reinforced
0,78 kg (1.71 lbs)
ingersollrandproducts.com
CAUTION
Condensate drainage which is reliable in performance
directly optimizes the compressed-air quality.
To prevent damage and breakdowns, it is imperative
to observe the following:
a.
Exact compliance with the specifications of use
and with the performance parameters of the ENL
10 Service-Unit, in connection with the case of
application (see "Proper use" section)
b.
Exact compliance with the installation- and
operation instructions in this manual
c.
Regular maintenance and control of the ENL 10
Service-Unit in accordance with the instructions in
this operating manual