14) TRIMMER
Trimmer
Min.
Max.
TCA
1
120
TW
2
210
TW.PED
5
60
15) DIP SWITCH
DIP
Default
Definition
Photocells during
OFF
1-2
opening
Block pulses during
3
OFF
opening
Automatic Closing
4
ON
Time
5
OFF
2-step logic
6
OFF
Pre-alarm
7
OFF
Deadman
Reduced work time
OFF
8
scale
ON
9
Photocell test
10
ON
Safety edge testing
16) DIAGNOSTICS and WARNINGS
Diagnostics
code
Steadily lit:
DL1
- Mains power on - Board powered - Fuse F1 intact
DL2
On when motor is activated during closing.
DL3
On when motor is activated during opening.
On:
DL4
-START input activated
-Radio receiver 1st channel activated
Off:
DL5
-STOP input activated
Off:
DL6
-PHOT photocell input activated
Off:
DL7
-SWC closing limit switch input activated
Off:
DL8
SWO opening limit switch input activated
On:
DL9
-PED pedestrian input activated
On:
DL10
-OPEN pedestrian input activated
On:
DL11
-CLOSE pedestrian input activated
Off:
DL12
-BAR safety edge input activated
On:
DL13
-With safety loop closed
17) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
17.1) TESTED DEVICES (Fig.O-P)
14 -
SP 3500
INSTALLATION MANUAL
Definition
Automatic closing time [s]
Motor work time [s]
Pedestrian work time [s]
Cross out
setting used
In the event beam is broken, photocell operation is disabled during opening. During closing, movement is reversed immediately.
ON
Logic enabled on Phot input.
In the event beam is broken, photocells are active during both opening and closing. When beam is broken during closing,
OFF
movement is reversed only once the photocell is cleared.Logic active on Phot input.
ON
The start pulse has no effect during opening.
OFF
The start pulse has effect during opening.
ON
Switches automatic closing on
OFF
Switches automatic closing off
ON
Switches to 2-step logic; with each pulse, start reverses movement.
OFF
Switches to 4-step logic.
ON
The flashing light comes on approx. 3 seconds before the motor(s) start.
OFF
The flashing light comes on at the same time as the motor(s) start.
Affects signals connected to terminals 26-33 and 26-34.
ON
Deadman mode: operation continues as long as the OPEN and CLOSE control keys are held down.
OFF
Pulse operation, according to 2, 3 or 4-step logic.
ON
TW work time falls within the range 1 to 90 seconds (pedestrian work time TW.PED range from 1 to 20 seconds)
OFF
TW work time falls within the range 3 to 210 seconds (pedestrian work time TW.PED range from 5 to 60 seconds).
Switches photocell testing off.
ON
Inhibits the photocell testing function, enabling connection of devices not equipped with supplementary test contacts.
OFF
Switches photocell testing on (Fig. O-P)
Switches safety edge testing off.
ON
Inhibits the safety edge testing function, enabling connection of devices not equipped with supplementary test contacts.
OFF
Switches safety edge testing on (Fig. O-P)
Description
www.BFTGateOpeners.com | (800) 878-7829
Waiting time before automatic closing.
Time motor(s) is/are powered for
Partial opening time for motor 2 following activation of PED pedestrian command.
Description
17.2) NON-TESTED DEVICES (Fig.H) one pair of photocells and one safety
edge.
18) WIRING DIAGRAM FOR BUILT-IN CONTROL UNIT Fig.Q-R
Description
Notes