Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation.
Electrical power MUST remain off until installation is complete.
Installer's hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out
rating of 1,000 lb.
Make sure that all water supply lines have been flushed and then completely turned off before beginning
installation. Debris in supply lines can cause valves to malfunction.
Read this entire installation manual to ensure proper installation. When finished with the installation, file
this manual with the owner or maintenance department. Compliance and conformity to local codes and
ordinances is the responsibility of the installer. Product warranties may be found under "Products" on our
Web site at bradleycorp.com.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging
material. If any parts are missing, do not begin installation until you obtain the missing parts.
For standard height mounting, do not exceed the recommended 34" distance from the top of the lav deck
to the finished floor. To meet ADA requirements, the lav deck cannot exceed the 34" maximum height
dimension.
215-1778 Rev. J: ECN 19-08-037A
© 2020 Bradley
Page 1 of 34
2/28/2020
Installation
LVLD2
Verge
®
with Evero
Patent Pending
Système lave-mains Verge
avec matériau au quartz naturel Evero
Brevet en instance
Sistema de lavabo Verge
con material de cuarzo natural Evero
Patente pendiente
WARNING
NOTICE
IMPORTANT
Lavatory System – LVLD-Series
Natural Quartz Material
®
®
P.O. Box 309
Menomonee Falls, WI 53052 USA
800 BRADLEY (800 272 3539)
+1 262 251 6000
bradleycorp.com
– Série LVLD
®
®
– Serie LVLD
®

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Bradley LVLD Serie

  • Página 1 To meet ADA requirements, the lav deck cannot exceed the 34" maximum height dimension. P.O. Box 309 215-1778 Rev. J: ECN 19-08-037A Menomonee Falls, WI 53052 USA © 2020 Bradley 800 BRADLEY (800 272 3539) +1 262 251 6000 Page 1 of 34 2/28/2020 bradleycorp.com...
  • Página 2: Tabla De Contenido

    Conjunto de desagüe ..................................30 Llaves y válvula de jabón opcional ..............................31 Montaje de la palangana ................................31 Filtro y sifón en P ..................................32 Adjuste la temperatura ..................................32 Cubierta del sifón ..................................33 Limpieza y mantenimiento ................................34 Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 3: Components

    *Standoff, Hex, SS #6-32 x 1" Drain O-Ring Adapter (125-111) Prepack (S45-2480) Drain Bowl Adapter Contact your Bradley Representative for color options Packing Washer Chrome P-trap (S29-094) Plastic P-trap (269-1697) #10-24 Screw *Screw #6-32 x 1-1/4" Pan *Included in Prepack S45-2778...
  • Página 4: Supplies Required

    • (7) 3⁄8" fasteners and wall anchors (minimum pull-out rating of 1,000 lb) • ½" hot/cold or tempered supply piping • 1½" NPT drain piping • OPTIONAL: 110V GFCI protected electrical outlet for 100–120V AC plug-in transformer (for Bradley Faucets) • Screen filter(s) as needed, if not included with faucet(s) (mm)
  • Página 5 TAS Height 34⁷/₁₆" (875) 33⁷/₈" (860) 27" 6⁷/₈" (686) (175) 16" (407) 14⁷/₈" (379) Juvenile and TAS, 12¾" Grades 6 thru 12 (324) 31⁷/₁₆" (799) 30⁷/₈" (784) 24" (610) 6⁷/₈" (175) 13" (331) Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 6: Rough-Ins

    #10 Anchors for Soap Tank Installation VERTICAL HEIGHT ADJUSTMENTS RIM HEIGHT FIXTURE STYLE FOR CODES A–E and H 33-7/8" None Standard Height, ADA, and TAS 30-7/8" Subtract 3" ADA Juvenile and TAS, Grades 6 thru 12 Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 7: Frame Mounting

    Finished Floor Fasteners (supplied by installer) 26" to secure backing to studs (660mm) Use 3/8" fasteners and square washers provided to secure the frame to the backing (5) places. Shim frame as necessary. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 8: Overflow Plug Assembly

    Standoff, Hex SS #6-32 x 1" O-Ring Drain Adapter Packing Washer #6-32 x 1-1/4" #10-24 Screw Screw Thread screw into drain adapter until it becomes fully engaged. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 9: Faucets And Optional Soap Valve

    Check to be sure the basin is level. 1/4"-20 Screw Press firmly on the back of the bowl to seat the bowl into the frame. Tighten the top screw on the frame. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 10: Strainer And P-Trap

    110°F (43°C) may Using cover, turn cartridge gently until cause scalding. desired water temperature is reached. Do not turn past stops as this may damage unit. Push cover down and tighten screw. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 11: Trap Cover

    Make all connections before installing trap cover. Hook Hang the trap cover onto Washer the hook, then secure the trap cover with the screws provided, starting with the #10-24 side screws. Screw Finishing Washer #10-24 Flat Head Screw Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 12: Cleaning And Maintenance

    Avoid contact with hot pans and objects. Repair Kits: Evero repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing. Repair kits are made to order and have a shelf life of 30 days.
  • Página 13 Pour les poses de hauteur standard, ne pas dépasser la distance conseillée de 34" (864mm) entre le dessus du rebord de lavabo et le sol fini. Pour être conforme aux exigences ADA, le rebord de lavabo ne devra pas dépasser la hauteur maximale de 34" (864mm). Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 14: Composants

    S53-3500, & S53-3700 Tuyau en Raccords plastique d’alimentation Tuyau en (Standard) plastique (S45-2510) Tuyau Trousse en acier tuyaux (S45-2999) inoxydable (S45-2731) Trousse tuyaux for Verge Faucets (S45-2730) S53-3100, S53-3300, S53-3500, & S53-3700 Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 15: Fournitures Requises

    • Filtre(s) à tamis selon les besoins, si non fourni(s) avec le(s) robinet(s) Dimensions Vue de dessus 15" 15" (381mm) (381mm) 9" 9" 6½" (229mm) (229mm) (165mm) 19½" (495mm) Vue de face 59½" (1512mm) 60" (1524mm) 33⁵/₈" (855mm) Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 16 TAS 34⁷/₁₆" (875mm) 33⁷/₈" (860mm) 27" 6⁷/₈" (686mm) (175mm) 16" (407mm) 14⁷/₈" (379mm) Enfant et TAS, 6e à 12e années 12¾" (324mm) 31⁷/₁₆" (799mm) 30⁷/₈" (784mm) 24" (610mm) 6⁷/₈" (175mm) 13" (331mm) Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 17: Raccordements

    AJUSTEMENTS DE LA HAUTEUR TYPE D’APPAREIL REBORD POUR LES CODES A–E et H 33-7/8" (860mm) Aucun Hauteur standard, ADA, et TAS 30-7/8" (784mm) Retrancher 3" (76mm) ADA, enfant et TAS, 6e à 12e années Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 18: Montage Du Bâti

    Utiliser des vis de 3/8" et des rondelles carrées pour attacher le bâti au renfort à cinq (5) emplacements. Placer des cales sous le bâti comme il se doit. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 19: Assemblage Du Bouchon De Trop-Plein

    à présent complètement engagée. Entretoise hexa, inox #6- 32 x 1" Joint torique Adaptateur d’écoulement Bague d’étanchéité n° 6-32 x 1-1/4" n° 10-24 Engager la vis à fond dans l’adaptateur d’écoulement. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 20: Robinets Et Vanne À Savon En Option

    3/8" (fournies par l’installateur). Vérifier que la vasque est de niveau. Vis de 1/4"-20 Appuyer fermement sur l’arrière de la vasque pour l’engager complètement dans le bâti. Serrer la vis supérieure sur le bâti. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 21: Tamis Et Siphon En P

    à une température pas endommager l’appareil, ne pas tourner au-delà des butées. Renfoncer le sans danger. Une eau à capuchon et serrer la vis. plus de 43 °C (110 °F) peut ébouillanter. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 22: Couvre-Siphon

    Accrocher le couvre-siphon sur le crochet, puis le fixer Rondelle avec les vis fournies, en commençant par les vis latérales. Vis n° 10-24 Rondelle de finition Vis à tête plate n° 10-24 Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 23: Nettoyage Et Entretien

    Trousses de réparation : Des nécessaires de réparation Evero sont disponibles. S’adresser au représentant ou distributeur Bradley pour connaître les numéros de références et les prix. Les trousses de réparation sont préparées sur commande et on une durée de conservation de 30 jours.
  • Página 24 Lav Deck hasta el piso terminado. A fin de cumplir los requisitos de las normas de ADA, la cubierta Lav Deck no debe exceder la dimensión de altura máxima de 34" (864mm). Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 25: Componentes

    Manguera (Standard) de plástico (S45-2510) Manguera (S45-2999) de acero Conjunto for Verge Faucets inoxidable Conjunto preempaquetado preempaquetado S53-3100, S53-3300, de manguera de manguera S53-3500, & S53-3700 (S45-2731) (S45-2730) Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 26: Materiales Necesarios

    • OPCIONAL: Tomacorriente eléctrico protegido por interruptor de circuito con pérdida a tierra (GFCI, por sus siglas en inglés) de 110 voltios, para transformador conectable de 100 a 120 V CA (para llaves Bradley) • Filtros de malla según sean necesarios, si no se incluyen con las llaves...
  • Página 27 33⁷/₈" (860mm) 27" 6⁷/₈" (686mm) (175mm) 16" (407mm) 14⁷/₈" (379mm) Para menores y TAS, desde 6º grado a 12º grado 12¾" (324mm) 31⁷/₁₆" (799mm) 30⁷/₈" (784mm) 24" (610mm) 6⁷/₈" (175mm) 13" (331mm) Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 28: Colocación De Las Tuberías Empotradas

    ESTILO DEL ACCESORIO BORDE PARA LOS CÓDIGOS A-E y H 33-7/8" (860mm) Ninguno Altura estándar, ADA, y TAS 30-7/8" (784mm) Reste 3" (76mm) ADA, para menores y TAS, desde 6º grado hasta 12º grado Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 29: Montaje De La Estructura

    (660mm) Use los sujetadores de 3/8" y las arandelas cuadradas que se proporcionan para fijar la estructura a los lugares de protección (5). Ponga cuñas en la estructura según sea necesario. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 30: Conjunto De Tapón Contra Desbordes

    6-32 x 1" Junta tórica Adaptador desagüe Arandela de empaquetadura Tornillo Tornillo n.º 6-32 x 1-1/4" n.º 10-24 Enrosque el tornillo en el adaptador de desagüe hasta que encaje completamente. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 31: Llaves Y Válvula De Jabón Opcional

    (proporcionados por el instalador). Compruebe que el lavamanos esté nivelado. Tornillo 1/4"-20 Presione firmemente la parte posterior de la palangana para fijarla a la estructura. Apriete el tornillo superior de la estructura. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 32: Filtro Y Sifón En P

    (43°C), puede provocar quemaduras. temperatura del agua que desee. No gire más allá de los topes, ya que se puede dañar la unidad. Presione la cubierta hacia abajo y apriete el tornillo. Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 33: Cubierta Del Sifón

    Arandela que se proporcionan, comenzando con los laterales. Tornillo n.º 10-24 Arandela de acabado Tornillo de cabeza plana n.º 10-24 Bradley • 215-1778 Rev. J: ECN 19-08-037A 2/28/2020...
  • Página 34: Limpieza Y Mantenimiento

    Kits de reparación: Existen kits de reparación de Evero. Comuníquese con el representante o distribuidor de Bradley para conocer los números de pieza y los precios. Los kits de reparación se hacen a pedido y se mantienen por 30 días.

Este manual también es adecuado para:

Lvld2