Installation
Not to scale; wiring omitted for clarity.
Upper Discharge pipe
Hose Coupling with Clamps*
Discharge pipe
cutoff piece
1-1/2"x1-1/4" Slip
Reducer bushing*
1-1/2"x 1-1/2" slip x
1-1/4" FNPT Tee*
Auxiliary Check Valve*
( See Note, Below )
1-1/2"x1-1/2" Slip Coupling*
1-1/2"x1-1/4" Slip Reducer
Bushing*
Primary Pump Discharge
Pipe (cut to fit)
Primary Sump Pump
††
Check Valve
Direction of Flow
Primary Sump Pump
Discharge Port
Notes:
* Supplied with the Battery Backup System.
Use if necessary to adapt a 1-1/4" discharge pipe to the 1-1/2" fittings supplied.
††
Do not use the auxiliary check valve if there is an existing check valve below the tee.
#
Use to adapt the auxiliary check valve to the discharge pipe.
##
Water level when the switch shuts off must be above the BBU pump intake.
Figure 2: Typical Installation Layouts
For parts or assistance, call Flotec Customer Service at
"Easy Install" Layout
††
#
##
Switch with Clamp*
1-1/4"x1-1/4"
Close Nipple*
1-1/4"x1-1/4"
Check Valve*
Check Valve Flapper(s)
must swing in direction shown.
1-800-365-6832
5
Alternate Installation
for a Shallow Sump
Teflon tape all
threaded joints
Battery Back Up
Sump Pump*
5763 0108