Mediclinics E85 Manual De Instalación Y Utilizacion página 13

Secador de manos
Tabla de contenido

Publicidad

www.mediclinics.com
The automatic model has proximity sensors mounted on the cover,
close to the air outlet.Therefore the sensor has to be connected during
the installation. Once the base fixed to the wall, after the follow-up of all
the steps shown in the sections "dismantling for installation" and
"mounting" the procedure is as follows:
1. Inside the cover you can find the sensors wire fixed by a subjection.
Detach it from its provisional subjection by taking care of not to pull the
wire (A).
2. Hold the cover without tightening the wire. Plug it into electronic plate
from the base, into the connector card wich you can find in the middle
and right side of same. There is only a position that fits smooth. Do not
force the connection (B).
3. When mounting the cover, take care that the sensors wire remains
under the black evolute of air ejection. For the assembly, insert the
cover into the base and screw the two lockscrews underneath.
INSTALLATION
Take always care of:
• Never tighten the wire.
• Not to force the connector's connexion.
• By handling it later recall not to pull the sensor's wire between the
base and the cover
Means for disconnection with contact separations at least 3 mm. (0,12")
must be incorporated in the fixed wiring.
During the installation process, the protection areas should be
considered according to norm VDE 0100. The hand dryer must only be
installed on a closed surface (wall, partition or similar).
-13-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

E88E88cE88csE88oE88bE85a ... Mostrar todo

Tabla de contenido