purchased, and selective collection by an approved organisation.
For further information, you can contact your local supplier or
local authority. Proper removal of waste electrical and electronic
equipment ensures proper processing and repurposing, thus
avoiding damage to the environment and harm to human health,
and protecting natural resources.
19. This product is intended for use at a maximum altitude of 3000 m.
EN
20. Always connect the earth conductor of the cable to the earth
ground or connect the earth conductor to the appropriate
terminal identified by the symbol
21. The instruction book of this product is available by contacting
the after-sales service (page 65).
22. See installation diagram (pages 70-72).
EN
1. PRODUCT MOUNTING See "General Warnings" N°.1 to N°.6
For product installation, refer to drawings section 1 page 70 to page 72.
2. HYDRAULIC CONNECTION See "General Warnings" N°.10 to N°.14
For hydraulic connection, refer to drawings section 2 pages 73-74.
- It is necessary to clean the supply piping prior to the hydraulic connection. The connection
to the hot water outlet is to be carried out with a dielectric connector, to avoid corrosion of
the pipe (direct contact iron / copper). The use of brass fittings is prohibited.
- Always install a new safety device on the cold water pipe of the water heater, which comply
with the standards (EN 1487 in Europe), with a maximal pressure of 0.7 or 0.8 MPa (7 or 8 bar)
according to the nominal pressure, with diameter matching in the input of the water heater.
- Do not use the safety valve included in this packaging in France (home country and French
overseas).
- The installation must have a pressure reducer if the supply pressure is over 0.5 MPa (5 bar).
The pressure reducer must be fitted at the main distribution outlet A pressure of 0.3 to 0.4
Mpa (3 to 4 bar) is recommended
What is more, if there is excess pressure, under no circumstances must the resulting flow be
slowed. Connect the safety unit to a drain pipe kept in the open air, in a frost-free environment,
with a permanent downward gradient, to remove any expansion water from the heater or the
water if the water-heater has to be drained. This means that the drainage tube diameter must
be suitable for the rate of flow.
INSTALLATION
.
62