intrOdUctiOn

Lincoln Model 3652 6-gallon Used Fluid Evacuator
is designed for evacuating fluids (except gasoline
or other fuels) from automotive reservoirs. Recom-
mended fluids include engine oil, gear and trans-
mission oils, power steering fluid, coolants, brake
fluid, and other similar fluids.
It utilizes a venturi that operates on compressed air
between 90 and 150 PSI (6 to 10 bar), to develop
vacuum in the 6-gallon (24-liter) tank. The vacuum
is transferred via an evacuation hose from the tank
to a wand or adapter, which is immersed into a res-
ervoir of fluid, and the fluid is drawn into the tank.

WarninGs and PrecaUtiOns

This equipment is designed for servicing a variety
of vehicles in a safe and convenient manner. How-
ever, due to the variation in vehicle design between
manufacturers, makes, models and years, oil
evacuation through the dipstick tube is not always
feasible or possible.
The procedures documented in this manual are to
serve as guidelines for general use of this equip-
ment. In addition to these guidelines, always follow
the vehicle manufacturer's recommended proce-
dures when attempting to use this equipment.
Use common sense when operating this equip-
ment. If something does not seem or feel right,
stop immediately and consult a professional with
knowledge of the application. Don't force the use
of this equipment on an application for which it is
not intended.
• Carefully read and understand these
instructions prior to using this equipment
• Always wear safety glasses when using this
equipment
• Avoid burns by remaining cautious of engine
parts that may become hot when the engine is
running
• Never operate this equipment on a vehicle with
the engine running
Page Number - 4

care and Maintenance

The evacuator does not require any particular
maintenance other than normal cleaning. The unit
should be cleaned using a cloth dampened with
water, alcohol, or detergent recommended for
household electrical appliances.
Connection
to Evacuation
Wand or Adapter
Valve A
Valve B
Evacuation Hose
Venturi
Sight Level Tube
Compressed
Air Connection
(90 - 150 psi /
6 - 10 bar)
Vacuum
Gauge