3. Installation Preparation.
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 10 feet (3.05m) from the floor and
30in. (76 cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
This fan can be mounted with a downrod on a
regular (no-slope) ceiling only. Fan CANNOT
mount as a flushmount installation nor on a
vaulted ceiling.
Installation requires these tools:
Phillips screwdriver, flathead screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
4. Hanging Bracket Installation.
Turn off circuit breakers to current fixture from
breaker panel and be sure operating light switch is
turned to the OFF position.
WARNING: Failure to disconnect power supply prior
to installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be
sure the outlet box is securely attached to the building
structure and can support the full weight of the fan.
Ensure outlet box is clearly marked "Suitable for Fan
Support." If not, it must be replaced with an approved
outlet box. Failure to do so can result in serious injury.
CAUTION: Be sure outlet box is grounded properly
and that a ground wire (green or bare) is present.
Install hanging bracket to outlet box using original
screws, spring washers and flat washers provided
with new or original outlet box.* Arrange electrical
wiring around the back of the hanging bracket and
away from the hanging bracket opening.
*Note: It is very important that you use the proper
hardware when installing the hanging bracket as this
will support the fan.
blade edge
30
inches
10 feet
(3.05m) (76cm)
downrod
installation
hanging bracket
spring washers
outlet box screws
page 3
12ft. - 20ft.
(3.66m - 6.1m)
flushmount
installation
CANNOT be
installed on
angled or
vaulted ceilings
flat washers