Bradley SN2003/TT Manual De Instalación página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SN2003/TT, SN2023/TT
Rough-In Dimensions for Supplies and Drain
Notes
Maximum flow rate required to washfountain is 1 .5 GPM . Size
supply lines accordingly .
Supplies from Below: Stub up 2-1/2" (64) .
Supplies from Above: Supplies must be located on centers of
dimensions shown to pass through washfountain shroud and
sprayhead .
Drain through floor: Stub up 3" (76) .
Supplies from Below or Through Wall
Type A
Off-line vent (P-Trap
supplied by Installer .)
2-3/4"
(70)
5"
(127)
C
C L
4-1/2"
(114)
H
5"
(127)
When running supplies and drain through wall, use same horizontal measurements as shown in Top View.
Position openings above the finished floor, at the following dimensions (to center):
Drain: Standard Height: 19-1/4" (305)
Juvenile Height: 15-1/4" (387)
Floor-mounted units: UPC and IPC restrict the vertical distance from the fixture outlet to the trap weir
to not more than 24" (610). Check state and local codes for variances.
4
Type H
Centrally rising vent
(P-Trap furnished
with unit .)
Top View
2-3/4"
(70)
C
4-1/2"
(114)
4-1/2"
(114)
H
5"
(127)
8-3/4"
(222)
10/20/2014
Type B
Centrally rising vent
(P-Trap furnished
with unit .)
2-3/4"
(70)
C
L
7-9/16"
(192)
8-3/4"
(222)
Supplies: Standard Height: 12" (305)
Juvenile Height: 8" (203)
Key
1/2" Supply: Nominal Copper Tube
1/2" Supply Through Wall (Optional):
Nominal Copper Tube
1-1/2" NPT Drain
1-1/2" NPT Vent
Supplies from Above
Top View
2-3/4"
(70)
27/32"
(21)
C
C L
H
27/32"
(21)
Bradley • 215-1758 Rev. A; ECN 14-00-007
Installation
(mm)
Type O
Off-line vent
(P-Trap supplied
by Installer .)
27/32"
(21)
C
C
L
27/32"
H
(21)
7-9/16"
(192)