Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe Talis E71760 Serie Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• 71740XXX: The diverter (type HC) installed in the
bath mixer is designed as an anti-retraction device.
For this reason, the lower edge of the diverter must
be at least 25 mm above the highest possible dirty
water level.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C / 4 min
Cause
- check valve hasn't moved back
- Shower filter seal dirty
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Flow limiter in handshower isn't re-
moved
- Shower filter seal dirty
- filter insert shower dirty
- check valve hasn't moved back
Assembly (see page 32)
• Safety against backflow
• The product is exclusively designed for drinking
water!

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 34)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions (see page 36)
Flow diagram (see page 36)
Spare parts (see page 38)
Cleaning (see page 37)
Maintenance (see page 40)
The check valves must be checked regularly according
to DIN EN 1717 in accordance with national or
regional regulations (at least once a year).
Operation (see page 35)
Test certificate (see page 40)
Remedy
- Exchange check valves
- Clean filter seal between shower
and hose
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Remove flow limiter
- Clean filter seal between shower
and hose
- Clean filter insert between shower
and hose
- Exchange check valves

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Talis e71740 serie

Tabla de contenido