9. START UP (plug&play).
Be sure that the pump is correctly primed
n
Connect the device to the electric supply with the magnetothermic switch, all the led lights will flash instantaneously for a second.
n
Screen will show SP (set pressure) and then its default value 2,0 bar, both displays are alternated in time periods of 1"/5" .
pq
By mean of
we can adjust the desired set pressure.
n
Press the push-button AUTO, the device will start to operate and led light AUTO ON/OFF will light. The screen will show the
n
instantaneous pressure. Being in automatic mode and using the push-buttons we can change the display:
P: instantaneous pressure (bar).
n
Fr: instantaneous speed.
n
A: instantaneous current consumption.
n
10. CONFIGURATION.
In the configuration menu we can adjust either maximum current (A) and minimum pump speed (FL). Next steps shoud be followed:
1. Press push-button MENU during 3 seconds to start the configuration sequence.
2. Input the nominal intensity value in Amps using
For the device must be within 0 and 7.5 A.
This value is located over the characteristics plate of the motor. Press ENTER for validation.
p
3. Using
can be increased the lower limit of the speed of rotation.
The value must be within 30 and 35 Hz. Default value is 30 Hz.
Press push-button ENTER, for validation and quit this menu.
4. System is ready. By mean of AUTO ON/OFF quit the manual operating mode.
EGISTER OF OPERATION DATA AND ALARMS.
11. R
By using simultaneously MENU +
of ENTER we can advance through the sequence, once finished the sequence we come back to the main display . This is all
the sequence:
REGISTER HOURS (HF). Counter of total time that the pump has been operating.
n
REGISTER STARTS (CF). Number of cycles of operation, a cycle is a start and a stop.
n
REGISTER SWITCH (Cr). Number of connections to the electric supply.
n
ALARM COUNT DRY RUN (A1). Number of dry-running alarms.
n
ALARM COUNT I MAX (A2). Number of overcurrent alarms.
n
ALARM COUNT. DISCONNECTED PUMP (A3). Number of disconnected pump alarms.
n
ALARM COUNT. TEMP (A6). Number of alarms by excessive temperature.
n
ALARM COUNT. SHORTCIRCUIT (A7). Number of short circuit alarms.
n
ALARM COUNT. OVERVOLTAGE (A8). Number of overvoltage alarms.
n
ALARM COUNT. UNDERVOLTAGE (A9). Number of undervoltage alarms.
n
All the records are saved even if the device has been disconnected from the electric supply.
Note: For quantities with more than 2 figures they will appear in consecutive screens after each ENTER. For example, to
indicate 10234 overcurrent alarms:
.....
pq
during 3" is acceded to REGISTER OF OPERATION DATA AND ALARMS, by mean
p
enabling the thermal protection.
-7-
ON
OFF
....