7.2.5. Diagnostic parameters

Index Dec
Parameter Name
(Hex)
Operating Hours
201 (0xC9)
Number of Power Cycles
202 (0xCA)
Maximum temperature
203 (0xCB)
– All time high
Minimum temperature
204 (0xCC)
- All time low
Maximum temperature since
205 (0xCD)
power-up
Minimum temperature since
206 (0xCE)
power-up
Current temperature
207 (0xCF)
Detection counter SSC1
210 (0xD2)
Minutes above Maximum
211 (0xD3)
Temperature
Minutes below Minimum
212 (0xD4)
Temperature
Maintenance event counter
213 (0xD5)
Download counter
214 (0xD6)
Access
Default value
RO
0
RO
0
RO
0
RO
0
RO
-
RO
-
RO
-
RO
-
RO
-
RO
-
RO
0
RO
0
Rev.00 - 02.2020 | CA18EA/CA30EA Capacitve sensors with IO-Link interface | © 2020 | CARLO GAVAZZI Industri
Data range
Data Type
0 ... 2 147 483 647 [h]
IntegerT
0 ... 2 147 483 647
IntegerT
-50 to 150 [°C]
IntegerT
-50 to 150 [°C]
IntegerT
-50 to 150 [°C]
IntegerT
-50 to 150 [°C]
IntegerT
-50 to 150 [°C]
IntegerT
0 ... 2 147 483 647
IntegerT
0 ... 2 147 483 647 [min]
IntegerT
0 ... 2 147 483 647 [min]
IntegerT
0 ... 2 147 483 647
IntegerT
0 ... 65 536
UIntegerT
Length
32 bit
32 bit
16 bit
16 bit
16 bit
16 bit
16 bit
32 bit
32 bit
32 bit
32 bit
16 bit
31