Electrical Connections - Hinkley HOVER FLUSH 52 Manual De Instrucciones

Ventilador led interior / exterior
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ELECTRICAL CONNECTIONS

REMEMBER -Turn off the power! NOTE - Control must be installed within 30 feet of fan.
Use the wire nuts supplied with your fan when making connections. Secure the connectors with electrical tape and make sure there are no loose
connections or wire strands.
Insert the receiver into the top of the fan housing. (Fig. 1) For best
1
performance, make sure the Black Antenna, on the end of the receiver,
remains extended and not tangled with any of the electrical wires.
Make wire connections from the fan to the receiver unit. For this
2
step use the bundle of 5 wires on the receiver. (Fig. 2)
Connect the YELLOW fan wire to the YELLOW receiver wire.
Connect the GRAY fan wire to the GRAY receiver wire.
Connect the RED fan neutral wire to the RED receiver neutral wire.
Connect the WHITE fan neutral wire to the WHITE receiver neutral wire.
Connect the BLUE fan neutral wire to the BLUE receiver neutral wire.
3
Connect the wiring from the ceiling to the receiver unit. (Use the 2 wire
bundle on the receiver.) Secure with supplied wire nuts.
Connect the BLACK building supply wire to the BLACK receiver wire.
Connect the WHITE receiver neutral wire to the WHITE building neutral
wire.
Connect the COPPER building ground wire to the YELLOW/GREEN fan
ground wire. Also connect the two GREEN wires (from fan) to building
ground wire.
Receiver
Fig. 1
BLK (AC IN)
WH (AC IN)
Receiver
BLUE (to motor)
WHITE (to motor)
RED (to motor)
GRAY (to motor)
YELLOW (to motor)
YELLOW (motor)
GRAY (motor)
RED (motor)
WHITE (motor)
BLUE (motor)
Fig. 2
©2019 Hinkley Lighting, Inc. | hinkley.com |
GROUND
Outlet box
Ceiling
Fan
07

Publicidad

Tabla de contenido

Solución de problemas

loading