POSITIONING
|
The dehumidifier is designed only for indoor use however, it can be placed inside or outside the room to be dried.
INTERNAL POSITIONING
When positioning the unit inside the room, place it centrally, ensuring inlet and outlet ducts are clear of
obstruction.
If required, ducts can be connected to the outlet and/or inlet to direct the drying to specific areas.
The Wet-Air-Out MUST be ducted outside the room.
EXTERNAL POSITIONING
When positioning the unit outside the room, connect ducting to the outlet to direct the dry air stream into the
room to be dried.
Optionally, the inlet may also be ducted to the room with the unit to give a re-circulation effect. In this case
however, because the unit uses a portion of the inlet air for regeneration, provision must be made in the inlet
duct to also draw air form outside the room.
Note:
As the Wet-Air-Out discharge is warm and very humid ensure it is directed where it will have no adverse effect
on the immediate environment.
All ducting lengths should be kept to a minimum —longer lengths will reduce performance.
The Wet-Air-Out is warm and very humid, when a duct is attached, condensation may form on the inside of the
duct. This duct should slope downwards away may from the unit to prevent any condensation running back
into the unit.
7