ENGLISH
1. INTRODUCTION
This instruction manual has been drafted
in accordance with the requirements of the
Machinery Directive CE 2006/42/EG. The
instruction manual is an integral part of the
lifting tower to be consulted before, during
and after tower's start-up, likewise whenever
deemed necessary, respecting the contents
for each and all the parts thereof.
This is the only way to achieve the basic ob-
jectives established in the manual's base such
as preventing accident risks and the maxi-
mum possible optimisation for the lifting
tower features.
This manual has taken extreme care regar-
ding safety and accident prevention at work
while using the machine, highlighting infor-
mation of particular interest to the user.
ATTENTION: BEFORE TO USING THE
LIFTING TOWER,
READ THIS MANUAL CAREFULLY
2. GENERAL DATA
2.1. Technical Data:
Name: LIFTING TOWER
Model: MEGARA 100
Technical characteristics:
Maximum height: 4m.
Minimum height: 1,66m.
Maximum load: 100kg.
Minimum load: 25kg.
Material: Steel EN 10305-5.
Open base area: 1,57 x 1,57m.
Closed base area: 0,36 x 0,36m.
Weight: 33kg.
Winch: 450kg maximum load with automa-
tic load retention brake.
Cable: Galvanized steel under EN 12385-4.
Cable maximum load: 956kg.
Cable torsion resistance: 1.770N/mm².
Cable diameter: 4mm.
Cable composition: 7x19+0.
Fixation of tower sections to working height
with safety pins.
Leg anchorage with safety pins.
Bubble level to adjust tower's vertical posi-
tion.
12
12
Equipment description:
Lifting tower MEGARA 100 has been desig-
ned to vertically raise structures and lighting
and sound equipment to different heights.
Tested by skilled personnel having passed all
the operating, maximum load and dimen-
sion inspections.
Company: FENIX Stage, S.L.
Address: Avda. de los Trabajadores, 24
Horno de Alcedo - 46026 - Valencia (Spain)
2.2. Applicable regulations
- Machinery Directive CE 2006/42/EG.
- BGV C1 (GUV 6.175).
- BGG 912 (GUV 66.15, GUV G-912).
- EN 12385-4:2008-06.
- DIN EN 10305-3:2010-05.
3. GENERAL SAFETY RULES
- The lifting tower is an industrial element designed to raise loads vertically, it must NEVER
be used as a platform elevator for people.
- Only place the lifting tower on firm flat grounds checking it is in vertical position. Do not
use wedges or any strange elements to balance the hoist.
- Check legs are correctly assembled and secured by their safety pins.
- Never raise a load without first checking it is correctly supported and centred on the appro-
priate lifting tower supports, so the load only acts vertically.
- Never surpass the maximum load capacity indicated on the lifting tower characteristics label
and on this instruction manual.
- Never use a ladder over the lifting tower or lean against it for any kind of work.
- Beware of any kind of projection above the lifting tower like cornices, balconies, luminous
signs, etc. It is very important to avoid the presence of cables below the lifting tower's working
height.
- Never move the lifting tower when the load is raised. It is inadvisable to make any kind of
movement, even small positioning adjustments.
- Never use the lifting tower over any mobile surface or vehicle.
- Before using the lifting tower, check the cable's state, which must not present any broken
threads or compression. NEVER use defective cables and change cable if in doubt. Only use
steel cable as described on this manual.
- Fix the lever when the load is raised.
- Neither grease nor lubricate the winch brake mechanism. Braking disks were greased with a
special heat and pressure resistant grease.
- No other products must be used to prevent negative influence on brake functioning.
- All sections of the lifting tower must be lowered to transport it.
ENGLISH
13
13