interior
5/6/06
• Unplug the appliance when not in use,
before moving it, and before carrying out any
cleaning or maintenance.
• Never pull on the cable to remove the plug.
• Do not place any heavy or hot objects on the
appliance.
• Do not allow children to handle or play with
the appliance.
• Do not push any objects through the air
inlet/outlet grilles as this could be dangerous
when the fan is running at high speed.
• Do not cover the air inlet/outlet grilles.
• Do not use the appliance in narrow, sealed
rooms.
4. FOR CORRECT FUNCTIONING
• Place the appliance on a flat, stable surface.
• A space of at least 50 cm must be left free
around the appliance to guarantee correct
functioning.
• Close the doors and windows of the room in
which the appliance is to be used.
• The temperature in the room in which the
appliance is to be used must be between
5ºC and 35ºC. If the temperature exceeds
these limits the compressor will stop working.
• If the ambient temperature is lower than 5º
C, the absolute humidity will be very low and
it will therefore not be necessary to use the
dehumidifier.
• When the appliance stops, wait around 5
minutes before starting it up again.
• Do not place any objects or pour any liquids
into the water tank.
5. CONTROL PANEL (6) (FIG. 2)
6.1
Green on/off pilot light: This lights up
when the appliance is switched on,
and goes off when it stops.
6.2
Red tank full pilot light: This lights up
if the tank is not fitted to the appliance
or if it is not fitted correctly. When this
pilot light comes on the appliance will
switch off.
6.3
Defrost pilot light: When this pilot light
is on, it means the internal defrost
system is functioning and the
compressor has stopped.
10:35
Página 9
6.4
Humidistat: this regulates the Relative
Humidity. The adjustment values are
between 40% and 80% RH.
0 =
Off
Cont = Continuous functioning position.
The middle position (fig. 3) corresponds to
55%-65% RH.
6. STARTING UP THE APPLIANCE
1
Ensure the humidistat (6.4) is turned
to "0".
2
Plug the appliance in. Check the red
tank full pilot light (6.2) is off.
3
Turn the humidistat (6.4) to "Cont" for
continuous functioning. The green
on/off pilot light (6.1) will come on.
Keep the humidistat (6.4) in this
position until the relative humidity in
the atmosphere drops to the desired
level. Then slowly turn the humidistat
(6.4) in the opposite the direction until
the appliance stops and the green
pilot light (6.1) goes out. In this
position the appliance will start and
stop automatically, maintaining the set
degree of humidity.
The ideal ambient conditions for well-
being are between 50% and 60%
relative humidity.
4
To stop the appliance, turn the
humidistat (6.4) to "0" and unplug the
appliance.
Important: If the degree of humidity set is
higher than the ambient humidity, the
dehumidifier will not function.
7. DRAINING OFF THE
CONDENSATION WATER
The condensation water can be drained off
in two ways:
Tank (4):
The condensation water is collected directly
in the tank (4).
When the tank is full, the red pilot light on
the control panel (6.2) will come on and the
appliance will automatically switch off.
The tank must then be emptied and fitted
correctly back onto the appliance (Fig. 4) so
10