Switched (daisy chain) connection

Dante devices can be daisy-chained when there are few
connected devices and when not using a switching hub. Connect
them as shown below.
8 Switched (daisy chain) connection example
IF-DA64 /
Mixer
NOTE
When using a switched (daisy chain) connection, connect
to either the PRIMARY or SECONDARY connector.
If the number of connected devices increases, raising the
latency setting will be necessary.

Redundant connection

For recording situations where retakes are not possible, including
live performances, a connection set up like the following uses two
completely independent primary and secondary networks.
IF-DA64 /
DA-6400
DA-6400
8 Redundant connection example
Primary
PC
HUB
NOTE
Settings for switched (daisy chain) and redundant
connections do not change automatically. Change the
settings on the Dante Controller Network Config screen.
CAUTION
The primary and secondary networks cannot be
connected to each other in any way.
Do not connect the primary and secondary networks to
the same switching hub.
Secondary
Primary
Secondary
Mixer
IF-DA64 /
HUB
DA-6400
IF-DA64 /
DA-6400
Hub