Status
4 LEDs light.
3 LEDs light.
2 LEDs light.
1 LED lights.
1 LED flashes.
Battery state of charge cannot be displayed while the control switch is pressed and for up to 5 seconds
after releasing the control switch. If the LEDs of the charge state indicator flash, follow the instructions
in the 'Troubleshooting' section.
3.5
Items supplied
Crimping / pressing tool, operating instructions.
Other system products approved for use with this product can be found at your local Hilti Store or online at:
www.hilti.group | USA: www.hilti.com.
4
Technical data
Rated voltage
Weight in accordance with EPTA procedure 01
Crimping time
Max. crimping force
4.1
Noise information and vibration values in accordance with EN 60745
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure. The data given represents the main applications of the power tool.
However, if the power tool is used for different applications, with different accessory tools, or is poorly
maintained, the data can vary. This can significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the
total working period. Identify additional safety measures to protect the operator from the effects of noise
and/or vibration, for example: Maintaining the power tool and accessory tools, keeping the hands warm,
organization of work patterns.
Noise values
Sound (power) level (L
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Vibration values
Total vibration (during operation) (a)
Uncertainty (K)
4.2
Battery
Battery operating voltage
Ambient temperature
Storage temperature
2188464
*2188464*
Printed: 14.06.2018 | Doc-Nr: PUB / 5367417 / 000 / 01
)
WA
)
WA
)
pA
)
pA
Meaning
State of charge: 75 % to 100 %
State of charge: 50 % to 75 %
State of charge: 25 % to 50 %
State of charge: 10 % to 25 %
State of charge: < 10 %
NPR 019 IE-A22
21.6 V
2.32 kg
≈ 4 s
19 kN
80 dB(A)
2.5 dB(A)
70 dB(A)
2.5 dB(A)
2.5 m/s²
1.5 m/s²
21.6 V
−17 ℃ ... 60 ℃
−20 ℃ ... 40 ℃
English
15

Publicidad

Tabla de contenido
loading