3 Safety instructions

3.1

Safety aspects

Safe execution of the procedures in this manual requires technical experience and a general knowledge
of safety precautions as well as a general knowledge of the human loco-motor system.
Warnings, Cautions and Notes have been used throughout the manual to bring special matters to the
reader's immediate attention.
A Warning concerns danger to the safety of the user or technician;
A Caution concerns an act that might damage the equipment;
A Note highlights a statement that deserves more emphasis than the general text, but which
does not merit a Warning or a Caution.
It is important to follow the correct sequence of steps in a procedure to ensure safe handling of the
equipment and the prevention of damage. Never, therefore, change the sequence of a procedure.
3.2

Legal aspects

This manual and the information it contains are the property of Enraf-Nonius B.V. (The Netherlands.)
Enraf-Nonius B.V. disclaims any responsibility for personal injury and/or damage to equipment caused by:
Negligence or disregard of a Warning or a Caution.
Deviation from any of the described procedures.
Performance of activities that are not described in this manual.
Ignorance of the general safety precautions for handling tools and the use of electricity.
Usage of the device in a manner other than that specified in this manual.
3.2.1

Warnings

All the cardiovascular training equipment is intended for use under (para)medical supervision.
The operator shall take notice of the physical and mental condition of the patient and, to his
judgement, decide whether exercising is admissible.
Stop the training immediately if the patient feels unwell or dizzy, or if he/she experiences cardiac
pathology symptoms!
Check that your patients are complying with the pre-set maximum heart rate limit, and stop the
training immediately if this limit is exceeded.
When using the Polar® chest strap, a sufficient distance (at least 1.5 metres) must be allowed
between users. If not, there is a risk that the pulse measurement will be distorted.
In case of a dermatological condition, injured skin shall never contact the keyboard, heart-rate
sensor, ear sensor, hand sensor, saddle, handlebar or pedals.
Be assured that all adjustable items (levers etc.) are properly adjusted with respect to each other
and well tightened. Note, danger of injury!
3.2.2

Caution:

A check shall be carried out on the packaging and on the device and for deterioration, before
putting the Bike Reha into use.
The Bike Reha must be connected to a 230V/50Hz outlet. If the wrong voltage is used then the
Bike can be damaged or may function incorrectly.
The Bike Reha shall not be installed in a location near a heat source. Exposure to direct sunlight
shall be avoided.
The device shall not be used in close proximity (i.e. less than 5 metres) of short-wave and
microwave equipment.
Never insert your hand under the cover! Through the open underside you can come into contact
with the pedal mechanism, the belt or the brake. There is a risk of injury when the pedal shaft is
rotating!
When any maintenance or service work is being performed and whenever the side-cover of the
housing is removed the Bike Reha must be disconnected from the mains!