7 Installer Setup Service Setup; Pump Maximum Speed; Pump Down - Panasonic WH-SXC09H3E5 Instrucciones De Funcionamiento

Ocultar thumbs Ver también para WH-SXC09H3E5:

Publicidad

Idiomas disponibles

Idiomas disponibles

Menus
For installer
Menu

7 Installer setup Service setup

7.1

Pump maximum speed

To set the maximum speed of
the pump.
7.2

Pump down

To set the pump down
operation.
22
Default Setting
Setting Options / Display
Sterilization
Sterilization may be set for 1 or
more days of the week.
Sun / Mon / Tue / Wed / Thu / Fri / Sat
Sterilization: Time
Time of the selected day(s) of the week to
sterilize the tank.
0:00 ~ 23:59
Sterilization: Boiling temp.
Set boiling temperatures
65 °C
for sterilize the tank.
Sterilization: Ope. time (max)
Set sterilizing time
0:10
(in hours and minutes)
Setting the flow rate, max. duty and operation
ON/OFF of the pump.
Flow rate: XX:X L/min
Max. Duty: 0x40 ~ 0xFE,
Pump: ON/OFF/Air Purge
Pump down operation
ON