DOOR OPENING TIME The position of the rotary switch (DOOR TIME) determines the activation time of
the door lock.
Pos. 0 = 1 s
Pos. 1 = 10 s
Pos. 4 = 40 s
Pos. 5 = 50 s
Pos. 8 = 80 s
Pos. 9 = 90 s
GUARANTEED CONVERSATION TIME The position of the rotary switch (CONV TIME) determines a
guaranteed conversation time, i.e. extends the busy time from the answer onwards.
The busy time is equal to the reply time (max. 60s) added to the guaranteed conversation time.
Pos. 0 = 1 s
Pos. 1 = 10 s
Pos. 4 = 40 s
Pos. 5 = 50 s
Pos. 9 = NOT ALLOWED
§
The guaranteed conversation time must be programmed in the same way for all system call stations.
ADVANCED CONFIGURATION
To go to advanced configuration, put both the rotary switches on position 9.
The door unit emits an acoustic signal and turns the signalling yellow led on.
At the end of operations, put again the door unit in stand-by mode, changing the position of one of the
rotary switches at least.
CONTROL CAMERAS
If in a call module are present the control cameras, the function must be programmed.
1. Go to the advanced configuration, by setting both the rotary switches to position 9; the door unit emits
a beep to indicate the programming state and turns the yellow led on.
2. Press the hall button (PA – CT) for the same times number as the present control cameras number. Each
time the button is pressed, the door unit emits the same beep number as the programmed cameras
number (5 max); by pressing again the button after 5 beeps, a long beep is emitted, to indicate that 0
cameras are connected (default).
3. Put again the rotary switches on the correct position to exit from the advanced configuration. The yellow
led turns off.
BUTTON CODES
Up to 62 buttons (in addition to the basic buttons) may be connected to the door unit using up to 4 button
expansion modules Ref. 1083/17.
By default the buttons are associate to the users from 0 to 63 of the column to which it belongs if the door
unit is configured as secondary unit.
If instead the door unit is configured as main unit, then the buttons are automatically associated to the
column 0, which simplifies the installation of main units in single column systems.
Instead, if the door unit is configured as main unit and several columns are present in the system, an
14
Pos. = 0 s
Pos. 6 = 60 s
Pos. = 0 s
Pos. 6 = 60 s
P5÷P8
P9÷P12
1083/17 (1)
P1÷P4
P13÷P16
INPUT
OUTPUT
Pos. 3 = 30 s
Pos. 7 = 70 s
Pos. 3 = 30 s
Pos. 7 e 8 = 70 s
P5÷P8
1083/17 (4)
P1÷P4
OUTPUT
P9÷P12
P13÷P16