CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING:
DANGER
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS
OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON
MONOXIDE POISONING AND / OR ELECTRIC SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE
OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS
MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID
WARNING
COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR
CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY
THESE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY
CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE,
SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS.
Model Numbers
REM-80V-LPC-O / REM-200V-LPC-O
CONVECTION HEATER
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989
Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com
User's Manual &
Operating Instructions
© 2017 Pinnacle Climate Technologies, Inc. RGL -402

Publicidad

Capítulos

Tabla de contenido
loading

Resumen de contenidos para Pinnacle Remington REM-80V-LPC-O

  • Página 1 CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS. 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989 Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com © 2017 Pinnacle Climate Technologies, Inc. RGL -402...
  • Página 2: Tabla De Contenido

    ANSI Z83.7-2011/CSA 2.14-2011. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS. Other standards govern the use of fuel gasses and heating products for specific uses. Your local authority can advise you about these. © 2017, Pinnacle Climate Technologies, Inc. Convection Heater User's Manual...
  • Página 3: Safety Information

    (2,800 sq cm) opening of outside air for Minimum Clearance From Combustibles every 100,000 Btu / Hr heater rating. Refer to Sides “Ventilation” on page 8 for further instructions. 48 in. 96 in. © 2017, Pinnacle Climate Technologies, Inc. Convection Heater User's Manual...
  • Página 4 / regulator assembly for storage. The Propane (LP) gas CAUTION 2. Remove all items from carton pressure regulator and hose assembly supplied with the heater must be used without alteration. © 2017, Pinnacle Climate Technologies, Inc. Convection Heater User's Manual...
  • Página 5: Specifications And Features

    Specifications subject to change without notice. Features REM-80V-LPC-O Upper Shell Lower Shell Base Inlet Connector Gas Valve Knob Figure 2 REM-200V-LPC-O Upper Shell Lower Shell Base Control Valve Inlet Connector Figure 3 © 2017, Pinnacle Climate Technologies, Inc. Convection Heater User's Manual...
  • Página 6: Assembly

    NOTE: Save carton and packaging material 3. Attach three (3) screws to the bottom row of for later storage. holes in the lower housing. (See Figure 5) Figure 4 Figure 5 © 2017, Pinnacle Climate Technologies, Inc. Convection Heater User's Manual...
  • Página 7: Operation

    The disconnected tank must cylinder. CAUTION never be stored in a building, – The heater must operate on vapor withdrawal garage or any other enclosed area. from the operating cylinder. © 2017, Pinnacle Climate Technologies, Inc. Convection Heater User's Manual...
  • Página 8 – Turn heater gas valve knob and LP cylinder connection. If the leak persists after several valve to OFF position. tries, contact Pinnacle Customer Service at (800) 676-1989. – LP cylinder valve equipped with old style fitting has LEFT HANDED THREADS. Turn –...
  • Página 9 5 minutes. 2. Rotate valve cylinder CLOCKWISE to close it. 2. Relight following the Lighting Instructions, steps 1-7. Shut Down Instructions 1. Rotate valve cylinder CLOCKWISE to close it. © 2017, Pinnacle Climate Technologies, Inc. Convection Heater User's Manual...
  • Página 10: Ventilation

    Re-gap the terminals to 0.195” (4.9 mm). fitting from damage. © 2017, Pinnacle Climate Technologies, Inc. Convection Heater User's Manual...
  • Página 11: Troubleshooting Guide

    3. Gas pressure too low. 3. Be sure regulator is operating properly. Burner flame is too low 4. Fuel supply too low. 4. Replace low fuel supply with new, full cylinder. © 2017, Pinnacle Climate Technologies, Inc. Convection Heater User's Manual...
  • Página 12: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Exploded View REM-80V-LPC-O REM-200V-LPC-O Figure 8 © 2017, Pinnacle Climate Technologies, Inc. Convection Heater User's Manual...
  • Página 13: Warranty

    CONNECTED TO A FUEL SOURCE LIMITED WARRANTY Pinnacle Climate Technologies, Inc. warrants this heater If Pinnacle Climate Technologies, Inc. finds the item to to the original retail purchaser only, to be free from defects be in normal operating condition, or not defective the item in material and workmanship for a period of one (1) year will be returned freight collect.
  • Página 14 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989 Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com © 2017 Pinnacle Climate Technologies, Inc.
  • Página 15 SUSPENDIDOS EN EL AIRE NI PRODUCTOS COMO GASOLINA, DISOLVENTES, SOLVENTES DE PINTURA, PARTÍCULAS DE POLVO O SUSTANCIAS QUÍMICAS DESCONOCIDAS. 1 Industrial Blvd #101, Sauk Rapids, MN 56379, EE.UU. • Llamada sin costo (866) 676-1989 Fax: 320-251-2922 • Web: www.remingtonheater.com • Correo electrónico: info@pinnacleclimate.com © 2017 Pinnacle Climate Technologies, Inc.
  • Página 16 DE INCENDIOS DE SU LOCALIDAD SI TIENE ALGUNA DUDA SOBRE EL USO DE ESTE CALENTADOR. Otras normas rigen el uso de gases combustibles y productos de calefacción para usos específicos. Sus autoridades locales pueden asesorarle sobre esas normas. © 2017, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de convección...
  • Página 17: Información Sobre Seguridad

    100,000 Btu/h que genere el calentador. Consulte Lados Superior “Ventilación” en la página 8 para obtener más 48 pulg. (1.2 m) 96 pulg. (2.4 m) instrucciones. © 2017, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de convección...
  • Página 18 Propano (LP) suministrado con este calentador 2. Retire todos los artículos de la caja de envío. debe utilizarse sin hacerle ninguna alteración. © 2017, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de convección...
  • Página 19: Características Y Especificaciones

    Coraza inferior Base Conector de entrada Perilla de la válvula de gas Figura 2 REM-200V-LPC-O Coraza superior Coraza inferior Base Válvula de control Conector de entrada Figura 3 © 2017, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de convección...
  • Página 20: Montaje

    3. Fije 3 (tres) pernos en los orificios de la hilera inferior de la cubierta inferior. (Vea la Figura 5) Figura 4 Figura 5 © 2017, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de convección...
  • Página 21: Operación

    – El calentador debe funcionar con recuperación El tanque desconectado nunca del vapor del tanque. debe almacenarse en un edificio, garaje o cualquier otra área cerrada. © 2017, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de convección...
  • Página 22 – Gire la perilla de la válvula de gas del cliente de Pinnacle al (866) 676-1989. calentador y la válvula del tanque de LP a la – La instalación de su calentador debe cumplir posición OFF (apagado).
  • Página 23 2. Vuelva a encender siguiendo los pasos 1-7 de para cerrarla. las Instrucciones para encender. Instrucciones para apagar 1. Gire la válvula del tanque hacia la DERECHA para cerrarla. © 2017, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de convección...
  • Página 24: Ventilación

    Reajuste la separación de las terminales a 0.195 pulg. (5 mm). © 2017, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de convección...
  • Página 25: Guía De Solución De Problemas

    3. Asegúrese de que el demasiado débil. regulador esté funcionando correctamente. 4. El suministro de combustible 4. Reemplace el suministro de es insuficiente. combustible insuficiente por un tanque nuevo. © 2017, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de convección...
  • Página 26: Vista Detallada

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE Vista detallada REM-80V-LPC-O REM-200V-LPC-O Figura 8 © 2017, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de convección...
  • Página 27: Garantía

    SIN LIMITACIONES, LAS GARANTÍAS IMPLÍCITAS DE defectuosas en uso y servicio normales dentro del periodo COMERCIALIZACIÓN Y APTITUD PARA UNA APLICACIÓN de la garantía, y lo cual lo determinará Pinnacle Climate EN PARTICULAR. ADEMÁS, Pinnacle Climate Technologies, Inc. a su discreción razonable.
  • Página 28 1 Industrial Blvd #101, Sauk Rapids, MN 56379, EE.UU. • Llamada sin costo (866) 676-1989 Fax: 320-251-2922 • Web: www.remingtonheater.com • Correo electrónico: info@pinnacleclimate.com © 2017 Pinnacle Climate Technologies, Inc.

Este manual también es adecuado para:

Remington rem-200v-lpc-o

Tabla de contenido