Your serial number can be found on the heater's rating label. It will begin with the letters PGCV
followed by 8 digits. For Example: PGCV12345678. Have your Serial Number ready before calling
customer service at 1-866-676-1989.
DANGER
DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS
OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING AND /
OR ELECTRIC SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD
USE OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.
WARNING
PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE
HEATER AS RECOMMENDED BY THESE INSTRUCTIONS. NEVER
USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN
VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH
AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES
OR UNKNOWN CHEMICALS.
MODEL NUMBER
REM-18-PCH-O
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND IN-
STRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN
FIRE, BURN, INHALATION, AND EXPLO-
SION HAZARD. KEEP SOLID COMBUS-
TIBLES, SUCH AS BUILDING MATERIALS,
Fax: 320-251-2922 • Web:
CABINET HEATER
User's Manual &
Operating Instructions
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free
www.remingtonheater.com
© 2018 Pinnacle Climate Technologies, Inc.
Factory ID: 515
(866) 676-1989
• Email: info@pinnacleclimate.com
RGCC-402

Publicidad

Capítulos

Tabla de contenido
loading

Resumen de contenidos para Pinnacle Remington REM-18-PCH-O

  • Página 1 VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS. 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989 Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com © 2018 Pinnacle Climate Technologies, Inc. RGCC-402...
  • Página 2: Tabla De Contenido

    This product can expose you to chemicals, including lead, which WARNING are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. © 2018 Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual...
  • Página 3: Safety Information

    NOT TOUCH. KEEP CHILDREN, ANIMALS, opening of outside air for every 100,000 Btu / Hr CLOTHING AND COMBUSTIBLES AWAY heater rating. Refer to “Ventilation” on page 9 FROM HEATER. for further instructions. © 2018 Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual...
  • Página 4: Specifications

    Heat Settings Maximum Operating Hours 65 / 36 / 24 Required Cylinder Lbs. Fuel Type Propane Heating Area (Ft. 165 / 300 / 450 Specifications subject to change without notice. © 2018 Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual...
  • Página 5: Features

    2. Remove all items from carton be used without alteration. 3. Check all items for shipping damage. If the heater is damaged, promptly inform dealer where you purchased the heater. © 2018 Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual...
  • Página 6: Assembly

    If assembly supplied with the heater must be the hose is cut or frayed, replace it with the used without alteration. manufacturer suggested assembly. Figure 1 Figure 2 © 2018 Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual...
  • Página 7: Operation

    – Handle valves with care. © 2018 Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual...
  • Página 8 3. Wait five (5) minutes for any gas to clear. Smell connection. If the leak persists after several for gas. If none is evident, proceed to the next tries, contact Pinnacle Customer Service at step. (866) 676-1989. 4. Push in the valve knob and turn to "PILOT".
  • Página 9: Ventilation

    REM-18-PCH-O output. Provide a larger opening if more 0.54 ft. heaters are being used. 501.7 cm Not for use in DANGER residential living areas or in non-adequately ventilated enclosed spaces. © 2018 Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual...
  • Página 10: Storage And Maintenance

    Always be sure that the heater has been allowed to cool for at least CAUTION 30 minutes before attempting to store, service, or perform mainte- nance. © 2018 Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual...
  • Página 11: Troubleshooting Guide

    5. Tip-over switch damaged, 4. Clean inside of heater housing. or loose connection at tip- 5. Inspect tip-over switch and switch. connections. Replace if 6. Out of fuel. necessary. 6. Replace LP cylinder © 2018 Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual...
  • Página 12: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE. EXPLODED VIEW PARTS LIST Item # Description REM-18-PCH-O Front Castor 50-011-0110 Rear Castor 50-011-0210 Piezo Button 50-014-0100 © 2018 Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual...
  • Página 13: Warranty

    WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR APPLICATION. FURTHER, Pinnacle use and service within the warranty period, and which Pinnacle Climate Technologies , Inc. shall determine at its Climate Technologies, Inc. SHALL HAVE NO LIABILITY reasonable discretion. WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
  • Página 14 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989 Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com © 2018 Pinnacle Climate Technologies, Inc.
  • Página 15 GASOLINA, DISOLVENTES, SOLVENTES DE PINTURA, PARTÍCULAS DE POLVO O SUSTANCIAS QUÍMICAS DESCONOCIDAS. 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Llamada sin costo (866) 676-1989 Fax: 320-251-2922 • Sitio web: www.remingtonheater.com • Correo electrónico: info@pinnacleclimate.com © 2018 Pinnacle Climate Technologies, Inc.
  • Página 16 Este producto puede exponerlo a sustancias químicas, incluyendo plomo, conocidas en el estado de California como causantes de cáncer y defectos de nacimiento u otros daños reproductivos. Si desea más información, visite www.P65Warnings.ca.gov. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador gabinete...
  • Página 17: Información De Seguridad

    72 pulg. (180 cm) 12 pulg. (30 cm) 24 pulg. (60 cm) reparación. Proporcione una abertura de al menos tres pies cuadrados (0.28 metros cuadrados) al aire © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador gabinete...
  • Página 18: Especificaciones

    65 / 36 / 24 funcionamiento Tanque requerido (lb) Tipo de combustible Propano Área de calefacción (pies 165 / 300 / 450 Las especificaciones pueden cambiar sin previo aviso. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador gabinete...
  • Página 19: Características

    3. Inspeccione todos los artículos por si concesionario a quien compró el calentador tuvieran daños por el envío. Si el calentador sobre dicho daño. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador gabinete...
  • Página 20: Montaje

    Tuerca de acoplamiento Figura 1 Figura 2 © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador gabinete...
  • Página 21: Funcionamiento

    – Trate las válvulas con cuidado. personales graves o la muerte. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador gabinete...
  • Página 22 Pinnacle al (866) 676-1989. 4. Presione la perilla de la válvula y gírela hasta – La instalación de su calentador debe cumplir con donde dice “PILOT”.
  • Página 23: Ventilación

    (29 kWh) de emisión del calentador. Si utiliza más 502 cm calentadores, provea una abertura más grande. No debe usarse en áreas habitables residenciales ni en espacios cerrados con ventilación inadecuada. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador gabinete...
  • Página 24: Almacenamiento Y Mantenimiento

    Siempre asegúrese de que el calentador pueda enfriarse por lo menos 30 minutos antes de tratar de almacenarlo, darle servicio o mantenimiento. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador gabinete...
  • Página 25: Guía Para La Solución De Problemas

    5. Inspeccione el interruptor o conexión suelta en el antivuelco y las conexiones. interruptor antivuelco. Reemplace si fuera necesario. 6. Combustible agotado. 6. Reemplace el tanque de LP. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador gabinete...
  • Página 26: Vista Detallada

    ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE. VISTA DETALLADA LISTA DE PIEZAS Pieza # Descripción REM-18-PCH-O Rueda delantera 50-011-0110 Rueda trasera 50-011-0210 Botón del piezoeléctrico 50-014-0100 © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador gabinete...
  • Página 27: Garantía Limitada

    Asegúrese siempre de especificar el número de modelo defectuoso. Pinnacle Climate Technologies, Inc. reparará y número de serie cuando haga algún reclamo a Pinnacle o reemplazará y devolverá el artículo, con el flete pagado Climate Technologies, Inc. Para su comodidad, use el por adelantado.
  • Página 28 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Llamada sin costo (866) 676-1989 Fax: 320-251-2922 • Sitio web: www.remingtonheater.com • Correo electrónico: info@pinnacleclimate.com © 2018 Pinnacle Climate Technologies, Inc.