089417 BA_Wandverteiler WV 4_16 4_32.qxp 07.02.18 15:31 Seite 15
WV 4/16A IP44 · WV 4/32A IP44

Wall mounting

To be used at the wall, the distribution box must be mounted to the wall using wall plugs and screws.
The recommended mounting height is with the controls at eye level.
The device is mounted using the mounting holes in the housing, see fig. B (11).
With this type of mounting, protection class II no longer applies without additional cover of the
mounting screws in the housing (dangerous voltage). If you would like to maintain protection
class II, cover the mounting screws with suitable protective caps.
117.6
2x 16
Fig. C: Drilling dimensions
– Mark the drilling dimensions at the wall according to fig. C.
– Select suitable fastening elements (wall plugs, screws) and observe the manufacturer's
specifications for installation (see introduction of Installation and commissioning section).
– Drill the holes and insert the wall plugs. Always consider electric cables which are already
installed in the wall.
– Loosen the housing screws, fig. B (10), using a suitable tool.
– Swivel the top of the housing, fig. A (2), downwards.
– Position the device at the wall aligning the mounting holes.
– Insert the mounting screws through the mounting holes, fig. B (11), of the bottom of the housing,
fig. A (1), and tighten them.
– Check that the device is secure.
– Close the top of the housing.
– Tighten the housing screws.
Check the connection of the sockets
– Supply the distribution box via the connection socket.
– Open the window, fig. A (4).
– Activate the protective equipment, fig. A (6).
– Check the voltage of each socket, fig. A (8) + (9).
280
116
250
250
15