Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

ROOF-MOUNT CURB
SOLAR POWERED
ATTIC VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, disable the ventilator by cover-
ing the solar panel with cardboard or disconnecting the wires
from the motor terminals (note wire locations when disconnect-
ing).
3. Installation work must be done by a qualified person(s) in ac-
cordance with all applicable codes and standards, including
fire-rated construction codes and standards.
4. If removing an existing 120 VAC powered attic ventilator, use
only a qualified person(s) to remove any electrical wiring in
accordance with all applicable codes and standards.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer's guidelines and safety standards such as those published
by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Condition-
ing Engineers (ASHRAE), and the local code authorities.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
TOOLS AND MATERIALS REQUIRED
r
Drill
r
1/4" Drill Bit
r
Sabre Saw or Keyhole Saw
r
Hammer
r
Ruler / Tape Measure
r
Pencil, Marker or Scribe
r
Utility Knife
r
Pry Bar (to remove roofing nails)
r
5/16" Socket and Extension
r
Roofing Cement
r
Galvanized Roofing Nails (1¾" min.)
MODELS 345CSOBK • 345CSOWW
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This unit has an unguarded impeller. Do not use in locations
readily accessible to people or animals.
4. This ventilator operates when the solar panel is exposed to
sun light. To reduce risk of injury while installing, servicing or
cleaning unit, cover the solar panel with cardboard or discon-
nect the wires from the motor terminals (note wire locations
when disconnecting).
5. The recommended open air inlet for this ventilator is 2 square
feet. The best location for these air intake vents are under the
eaves with direct access to the attic. Failure to provide these
intakes could cause natural-draft gas appliances to backdraft.
6. Your attic fan installation will create a screened opening into
your attic space. During a heavy rain storm there could be a
light spray of rain into this attic space. This is a normal condi-
tion with all attic ventilators and will not cause any damage to
the structure. We recommend that you do not store any valu-
able articles directly under the fan opening in the roof.
7. This ventilator is intended for roof installation. Broan Models
353 345GOBK & 345GOWW Gable Mount Ventilators are
available for side wall applications.
8. The plastic ventilator dome and base may be painted with
high quality paint. Follow the paint manufacturer's recommen-
dations for acrylic and ABS plastic as appropriate. Take care
to avoid getting paint on the solar panel.
9. This ventilator includes a permanently lubricated motor. Do
not oil or disassemble.
10. The installation instructions contained in this document are
only a recommendation and individual professionals may
have their own methods of installation. If your roof has an
existing warranty, installation of this product by anyone other
than those who installed the roof may jeopardize any future
warranty claim. Please check with the original installer of your
roof if this is a concern.
11. When working with asphalt shingles in cold weather (below
40
F), take care to avoid damage to the shingle edges and
o
corners.
12. For installations in climates where cold weather condensation
is not a concern, Broan Model CWT45 thermostat is available.
It disconnects power to the motor when the temperature drops
below 50
F. Power is applied to the motor when the tempera-
o
ture reaches 61
F.
o
Register your product online at:
www.broan.com/register
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan 345CSOBK

  • Página 1 6. When cutting or drilling into wall or ceiling, do not damage 7. This ventilator is intended for roof installation. Broan Models electrical wiring and other hidden utilities. 353 345GOBK & 345GOWW Gable Mount Ventilators are available for side wall applications.
  • Página 2 MODELS 345CSOBK • 345CSOWW Page 2 INSTALLATION Note: This ventilator is capable of replacing an existing 120 volt powered attic ventilator. Only a qualified per- son should remove any electrical wiring in accordance with local codes and standards. The illustrations in this section reflect an installation involving composite shingle roofing material.
  • Página 3 MODELS 345CSOBK • 345CSOWW Page 3 2" MIN. 19" 19" 8. Use the guide hole as a center point, use a nail and string to scribe a 14” diameter circle on the black paper or roof decking. 6. Taking into consideration the thickness of your chosen flashing material, build a 19”...
  • Página 4 MODELS 345CSOBK • 345CSOWW Page 4 CURB ROOF SHEET PANEL ASSEMBLY FLASHING CURB ROOF SHEET PANEL ASSEMBLY CURB BASE 11. Center the curb over the hole, ensure the top of curb is 15. Position the ventilator dome so the top points toward the parallel with the roof ridge and toenail in place.
  • Página 5: Service Parts

    MODELS 345CSOBK • 345CSOWW Page 5 SERVICE PARTS Replacement parts can now be ordered on our website. Please visit us at www.Broan.com Model Model 345CSOBK 345CSOWW Description (Black) (Weathered Wood) 77001311 77001313 Solar Panel Assembly (Dome) CWT45 CWT45 Thermostat (Optional)
  • Página 6 Customer shall properly notify Broan in writing and shall include with such notice a sales receipt or proof of purchase of the defective Product, and Broan at its option shall repair or replace the defective Product or component part without charge to Customer, except for: (A) costs incurred in transporting the Products or component parts to and from Broan’s designated dealer or its manufacturing plant in Hartford, Wisconsin;...
  • Página 7: Outils Et Matériel Requis

    Clous à toiture galvanisés de 4,4 cm (1¾ po) min. 12. Pour les installations dans les régions où la condensation par temps froid n'est pas un problème, le modèle Broan CWT45 thermostat est disponible. Il coupe le courant du moteur lorsque la température descend à...
  • Página 8 MODÈLES 345CSOBK • 345CSOWW Page 8 INSTALLATION Remarque : Ce ventilateur peut remplacer un ventila- teur électrique de 120 volts pour grenier. Seule une personne qualifiée peut enlever le câblage conformément aux codes et aux normes en vigueur. Les illustrations de cette section montrent une installation comportant des bardeaux en matériau composite.
  • Página 9 MODÈLES 345CSOBK • 345CSOWW Page 9 5 CM (2 PO) 2" MIN. MIN. 48 CM (19 PO) 19" 48 CM (19 PO) 19" 8. En utilisant toujours l'avant-trou comme point central, à l'aide d'un clou et d'une corde, tracez un cercle de 35,6 cm (14 po) de diamètre sur le papier noir ou le...
  • Página 10 MODÈLES 345CSOBK • 345CSOWW Page 10 ENSEMBLE DECADRE DE BORDURE SOLIN ENSEMBLE DE CADRE DE BORDURE BASE DU CADRE 11. Centrez le cadre sur l'ouverture, en vous assurant que 15. Positionner le dôme ventilateur de sorte que les points le haut est parallèle à la ligne du faîte et clouez-le en supérieurs vers l'arête de toit.
  • Página 11: Pièces De Rechange

    MODÈLES 345CSOBK • 345CSOWW Page 11 PIÈCES DE RECHANGE Les pièces de rechange peuvent être commandées sur notre site Web. Visitez notre site à www.Broan.com Modèle Modèle Repère 345CSOBK 345CSOWW Description (noir) (bois intempérisé) 77001311 77001313 Ensemble de panneau solaire (dôme)
  • Página 12 – Garantie exclusive limitée – Le contrat de garantie exclusive limitée (la « Garantie ») est conclu entre le client et Broan-NuTone LLC (« Broan »). Le client a lu attentivement cette garantie et convient que l’exécution des obligations de Broan ci-dessous lui fournira un recours adéquat qui servira aux fins essentielles de l’accord des parties relativement aux produits fabriqués par Broan et identifiés au verso de la présente (les...
  • Página 13: Ventilador Solar Para Ático De Montaje En El Bordillo Del Techo

    7. Este ventilador está diseñado para instalarse en el techo. Los Association, NFPA), y la Sociedad Americana de Ingenieros ventiladores para montaje en hastial Broan Modelos 353, en Calefacción, Refrigeración y Aire Acondicionado (American 345GOBK y 345GOWW están disponibles para aplicaciones Society for Heating, Refrigeration and Air Conditioning en muros laterales.
  • Página 14: Instalación

    MODELOS 345CSOBK • 345CSOWW Página 14 INSTALACIÓN Nota: Este ventilador tiene capacidad para reemplazar un ventilador para ático existente de 120 voltios. Sólo el personal calificado debe quitar el cableado eléctrico de acuerdo con los códigos y las normas locales.
  • Página 15 MODELOS 345CSOBK • 345CSOWW Página 15 2 PULG. (5 CM) 2" MIN. MÍN. 19 PULG. 19" (48 CM) 19 PULG. 19" (48 CM) 8. Utilice el orificio guía como punto central y con un clavo y un cordón marque un círculo de 14 pulg. (35.6 cm) de diámetro sobre el papel negro o la cubierta del techo.
  • Página 16 MODELOS 345CSOBK • 345CSOWW Página 16 CONJUNTO DEL PANEL DE PLACAS DEL TECHO DEL BORDILLO CONJUNTO DEL PANEL CUBREJUNTAS DE PLACAS DEL TECHO DEL BORDILLO BASE DEL BORDILLO 11. Centre el bordillo sobre el orificio, asegurándose de que 15. Coloque el domo del ventilador por lo que los puntos la parte superior del bordillo esté...
  • Página 17: Piezas De Servicio

    MODELOS 345CSOBK • 345CSOWW Página 17 PIEZAS DE SERVICIO Ahora se pueden hacer los pedidos de las piezas de repuesto en nuestro sitio Web. Visítenos en www.Broan.com Modelo Modelo Clave 345CSOBK 345CSOWW Descripción (Negro) (Madera curtida) 77001311 77001313 Conjunto del panel solar (domo)
  • Página 18: Garantía

    Garantía; ambos correrán a cargo del Cliente. No obstante cualquier disposición en la presente que señale otra cosa, esta Garantía no se ampliará para Broan ni la obligará a tomar medida alguna con respecto a: (A) Productos que hayan sido modificados, alterados, instalados, usados u operados de una manera que no sea recomendada por Broan, incluyendo cualesquiera Productos en los cuales se hayan instalado piezas no fabricadas ni aprobadas por Broan;...

Este manual también es adecuado para:

345csoww

Tabla de contenido