Telephone Helpline: 0845 146 2887
Installation
NOTE: If the unit has been moved or not stored in an upright position, let it stand upright for ap-
proximately 12 hours before operation. If in doubt, allow the appliance to stand.
1. Remove the appliance from the packaging. Make sure that all protective plastic film and coatings are
thoroughly removed from all surfaces
2. Maintain a distance of 20cm (7 inches) between the unit and walls or other objects for ventilation.
Increase the distance if the obstacle is a heat source
NOTE: Before using the appliance for the first time, clean the shelves and interior with soapy
water and rinse thoroughly.
Operation
Control Panel
The control panel is located below the doors on the rear of the appliance
Turn On
1. Close the doors of the appliance
2. Connect the appliance to a mains power supply
3. Press the
button to turn the light On or Off as required
Setting the Operating Temperature
1. Press the
button. The display will flash
2. Press the
or
3. Press the
button to store the temperature
Table of Controller Parameters
The operating parameters of this appliance have been preset for optimum performance and to maximise
the life of the appliance
Display
E1
E2
E3
E4
E5
E6
F1
F2
F3
F4
buttons to display the required temperature
Parameter
Lower set temperature
Upper set temperature
Temperature buffer
Temperature buffer time delay
Fixed parameter
Foxed parameter
Defrost period
Defrost interval
Defrost temperature
Centigrade/Fahrenheit
Preset Value
0°C
12°C
4°C
3 minutes
0
00
25 minutes
6 hours
20°C
0°C
UK
Range
-20°C to 2°C
2°C to 45°C
1°C to 10°C
0 to 10 minutes
DO NOT CHANGE
DO NOT CHANGE
1 to 60 minutes
1 to 24 hours
0°C to 22°C
°C/°F
3