Routine Maintenance Instructions - 10%
Step 1.
Unscrew LOWER END
ASSEMBLY from body.
Step 4.
Remove the #73 DOSAGE PISTON
GUIDE and replace #44 DOSAGE
PISTON and #14 O-ring.
Step 7.
Re-install the new #44 DOSAGE
PISTON and #73 DOSAGE PISTON
GUIDE. Tighten snug using a nut
driver.
English: 12
↓
Step 2.
Remove LOWER END ASSEMBLY .
↓
Step 5. Unscrew #72 ADAPTER and
remove.
Step 7a.
NOTE: #44 DOSAGE PISTON must
be installed flared end up.
Step 3.
Remove #93 CAPSCREW from the
end of the shaft using a wrench
and nut driver.
Step 6.
Remove and replace #17 O-RING
↓
Step 8.
Screw LOWER END ASSEMBLY
onto body. Hand tighten only.