Electrolux EXI09HL1W Manual De Instalación página 18

Bomba de calor inversor split
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

2 The yellow-green wire in air conditioner is
the earthing wire which can not be used for
other purposes. Improper earthing may cause
electric shock.
3 The earth resistance should accord to the
national wiring regulation.
terminal. Do not connect the earthing wire with
the following:
Water pipe
Gas pipe
Contamination pipe
Installation of Indoor
Electric Wires
1 Open the front panel and remove the wiring
cover by loosening the screw.
2 Route the power connection cable and signal
control wire (for heap pump model only) from
back of the indoor unit and pull it toward the
front through the wiring hole for connection.
3 Connect and screw the wires onto the
Black
Blue
Brown
17
All manuals and user guides at all-guides.com
Wiring cover
Earthing wire
(yellow-green)
Cable clamp
To
Outdoor
Unit
Wrap wires that are not connected with
insulating tape so that they do not touch any
electrical or metal parts.
clamp.
6 Put the wiring cover back and screw it.
7 Reinstall the front panel.
caution
All wires between indoor and outdoor units
contractor.
If the length of the power cord is not
enough, please contact your supplier for
new power cord. Lengthen the power cord
by yourself is not allowed.
After tightening the screws, pull the wire
Do not connect two power cables together
to supply power to the air conditioner.
Do not extend the power cable conductor
by cutting.
Installation of Outdoor
Electric Wires
1 Remove the handle on the right side plate of
outdoor unit by loosening the screw.
Handle
Terminal
block

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Exi12hl1wExi18hl1w

Tabla de contenido