4. Technical data
Designation
Temperature range
Environmental limits
Operation
Storage
Full range accuracy
Tamb = 25°C
Tamb = 23 +/- 3°C
Tamb = 23 +/- 3°C
Response time
Optics
Display
Displayed resolution
Distance to spot size
Spectral response
User selectable backlit display
User selectable laser + LED
Buttons
Emissivity
Laser pointers
Laser wavelength
Laser
Maximum laser power
Dimensions
Packed
Weight
Battery lifetime
Switch off
TKTL 11
-60 to 625 °C (-76 to 1 157 °F)
0 to 50 °C (32 to 122 °F)
10 to 95% R.H.
-10 to 60 °C (14 to 140 °F)
10 to 95% R.H.
Tobj = 15 to 35 °C, +/- 1.0 °C (1.8 °F)
Tobj = 0 to 625 °C, +/-2% of reading or
2 °C (4 °F) whichever is greater
Tobj = -60 to 0 °C, +/- (2 + 0.05/°) °C
1 000 msec (90%)
Sense emitted, reflected and
transmitted energy.
Color LCD
0.1 °C/F from -76~999.9,
otherwise 1 °C/F
16:1
8-14 µm
No, permanently ON
No, permanently ON
2 buttons. function as per instructions
for use
Pre-set 0.95
8 laser dots
635 - 660 nm
Class 2
1 mW
119.2 × 171.8 × 47.5 mm
(4.7 × 6.8 × 1.9 in)
White Carton Box
400 g (0.88 lb)
typical 12 hours, min 9 hours
continuous use with laser and backlight
Automatic after 15 seconds after
trigger is released
EN
7