Lenze L-force E94AZRS0044 Instrucciones Para El Montaje página 38

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4
Technical data
General data and operating conditions
Environmental conditions
Climate
Storage
Transport
Operation
Site altitude
Pollution
Vibration resistance
Transport
Operation
Mounting conditions
Mounting place
Mounting position
Free space
Mounting position
Standard
Variant
38
IEC/EN 60721−3−1
IEC/EN 60721−3−2
IEC/EN 60721−3−3
EN 61800−5−1
2
(9.81 m/s
= 1 g)
IEC/EN 60721−3−2
EN 61800−2
Germanischer
Lloyd
IEC/EN 60068−2−6
1K3 (−25 ... +60 °C)
2K3 (−25 ... +70 °C)
3K3 (−10 ... +55 °C)
Current derating at +45 ... +55 °C:
Device size 1 ... 7: 2.5 %/°C
Device size 8S ... 10: 1 %/°C
0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of 5 %/1000 m
Degree of pollution 2
2M2
2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
200 ... 500 Hz: acceleration resistant up to 15 m/s
5 ... 13.2 Hz: amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 1 g
In the control cabinet
Vertically
The required free space results from the mounting
position and the specifications of the standard device.
Footprint mounting; standard device is screwed on
the filter
Side−by−side mounting; filter is directly screwed to the
left of the standard device (
installation)
l
2
^
Mechanical
EDK94AZRS DE/EN/FR/ES/IT 6.1