Digital input - An alarm input for connecting devices that can toggle between an open and
closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a
signal is received the state changes an the input becomes active (shown under
Events > Port Status).
Function
Pin
GND
1
3.3 V DC
2
Power
Configurable
3-6 Digital input – Connect to GND to activate, or leave floating
(input or
Output)

Status indicators

Product
Color
AXIS Q6032
Unlit
AXIS Q6034
Amber
AXIS Q6035
Amber/red
Red
Green
Product
LED
AXIS T8123
Port
AC input
Notes
Ground
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
(unconnected) to deactivate.
Digital output – Uses an open-drain NFET transistor with the
source connected to GND. If used with an external relay, a
diode must be connected in parallel with the load, for pro-
tection against voltage transients.
Color
Unlit
Flashing
Green
Steady green
AXIS Q6032/Q6034/Q6035 Installation Guide
Indication
Steady connection/normal operation
Steady during system initiating and reset to factory
default. Flashes during firmware upgrade.
No network connection
Firmware upgrade failure
Steady for 10 sec. after successful restart
Indication
No camera connected
Power overload or other input voltage error
Camera connected, normal behavior
AC power connected
Specifications
Max. load = 250 mA
Min. input = -40 V DC
Max. input = +40 V DC
Max. load = 100 mA
Max. voltage = +40 V DC