Fagor DMT 8000 Manual Del Usuario página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING
Effect
"Status" LED colour: Green
"Status" LED colour: Orange
"Status" LED colour: Red
"Comm" LED colour: Orange
PROGRAM MISSING
TABLES NOT FOUND
OUT BW EXCEEDED
HW FAILLURE
LCN REPEATED
Cause
OK.
There are no tables in the input
Output Service disappeared
from transponder
No RF output
Image pixilation
Hardware failure
Waiting control data
Service not found
Defective Input Signal
Image pixilation
Hardware failure
LCN repeated
14
Action
Check input cable and DVB - ASI conections
Check OUTPUT SERVICES list; Read Services and check if any
program disappeared
Check if OUTPUT RF is "YES"
Check if Output Mux BW(%) is lower than 92%.
(OUTPUT SERVICES)
Switch OFF and ON again
Check Communication Bus between Modules and
MCU 8000. OK if there is no MCU 8000 unit
Read Services in OUTPUT SERVICES
Check input cable and DVB - ASI conections
Check if Output Mux BW(%) is lower than 92%.
(OUTPUT SERVICES)
Switch OFF and ON again
Check LCN repetition on active services

Publicidad

Tabla de contenido
loading