Gallagher S400 Instrucciones página 12

Ocultar thumbs Ver también para S400:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
• Install solar energizers on a post above the ground.
• Keep the solar panel clean (e.g. from dirt) periodically use a so cloth with
water and a mild detergent.
• Test voltage on the fence using a Gallagher Fence Volt Meter (G50301).
• Turn energizer off before handling fence or ba ery connec ons.
Symptom
Ba ery
indicator is
solid red
Ba ery
indicator
fl ashes red
Fence
Voltage
indicator
fl ashes red
No voltage
on fence
10
3E4097 Gallagher S400 Solar Energizer User Manual
Problem
Ba ery capacity is
low due to insuffi cient
sunlight. The energizer
will slow down to use
less power and allow
ba eries to charge.
No ba eries,
incorrect ba eries are
connected or ba eries
are damaged.
Output voltage is too
low, due to a high load
on the fence line.
Energizer may have
been damaged by
lightning.
Solu ons
Ensure energizer is ge ng enough
sun.
Turn energizer off for 3 days leave
in sun to charge ba eries.
Remove ba ery and use a 12 V 1.2A
charger to charge ba ery.
Connect the correct ba eries.
Replace both ba eries.
Check ba eries are OK using the
ba ery check func on.
Check fence and earth system for
faults.
Check energizer isn't faulty;
disconnect from fence and earth
measure across fence and earth
terminals with a Gallagher Fence
Volt Meter
-
if less than 5 kV return
energizer for service
-
if more than 5 kV the fault is
with the fence or earth system.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

G36130

Tabla de contenido