Troubleshooting - Intex PureSpa SSP-H-20-1 Manual Del Propietário

Ocultar thumbs Ver también para PureSpa SSP-H-20-1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
PROBLEM
NO DISPLAY/SPA
• Spa is unplugged or off.
• Control panel cable plug loose.
CONTROL UNIT DOES
• Power failure.
NOT WORK
• RCD tripped.
• RCD broken.
HOUSEHOLD CIRCUIT
• Circuit breaker under rated.
BREAKER TRIPPED
• Overloaded circuit breaker.
• An electrical fault in the line.
• Temperature set too low.
NOT HEATING
• Dirty fi lter cartridge.
PROPERLY
• Water temperature decreasing during
heater STANDBY mode.
• Heating element failed.
BUBBLE AIR BLOWER
• Air blower pump is too hot.
DOES NOT WORK
• Dirty fi lter cartridge.
FILTRATION PUMP
• Filtration inlet and/or outlet clogged.
NOT WORKING
• Filter pump motor failed.
WATER NOT CLEAN
• Cartridge assembly not properly attached.
• Insuffi cient fi ltering time.
• Dirty fi lter cartridge.
• Improper water maintenance.
• Filtration inlet and outlet clogged.
• One characteristic of PVC is that
PUMP CONNECTORS
it changes shape, which is normal.
ARE NOT LEVEL WITH
THE SPA CONNECTORS
TUB HAS A STRANGE
• Expanded internal air pressure by
SHAPE
strong sunshine.
TUB LOSES AIR
• Air valve cap loose.
• Air valve base loose.
PRESSURE
• Hole, cut or split on spa tub.
LEAKING BETWEEN SPA
• Spa control base inlet/outlet connections
TUB CONNECTORS AND
not securely tight.
CONTROL UNIT
• Spa control base inlet/outlet o-ring
missing/dirty.
CONNECTORS
• Control base components not securely
SPA IS TOO NOISY IN
FILTRATION MODE ONLY
attached.
• Control base ground not level and fi rm.
• Spa fi lter motor failed.
S AVE THESE INSTRUCTIONS

TROUBLESHOOTING

CAUSE
• Ensure the spa is plugged and switched on.
• Ensure the control panel cable plug is fi rmly
• Check power source.
• Reset the RCD.
• Contact Intex Service Center.
• Ensure correct circuit breaker rating.
• Provide a dedicated circuit breaker feeding the
• Contact a qualify electrician to correct the
• Increase the temperature and attach the spa
• Clean or replace the fi lter cartridge in time.
• If heater is in STANDBY mode, press the fl ame button
• Contact Intex Service Center.
• Turn off and unplug the spa. Let it cool down and
• If problem persists contact Intex Service Center.
• Clean or replace the fi lter cartridge in time.
• Check and clean fi ltration inlet and outlet regularly.
• Contact Intex Service Center.
• Ensure the cartridge assembly is properly attached.
• Increase fi ltration time.
• Clean or replace the fi lter cartridge in time.
• Keep the spa water properly sanitized. Refer to the
• Check and clean fi ltration inlet and outlet regularly.
• Elevate the pump with wood or another type of
• Do not expose the product under direct sunshine.
• Check the air pressure and release air if necessary.
• Ensure air valve cap is securely closed.
• Fill up the spa tub with air then make sure the
• Put liquid soap and water in a squirt bottle and spray on
• Tighten inlet and outlet connections.
• Coat the o-ring with petroleum jelly for water proof.
• Remove grid from inside spa with a screwdriver,
• Ensure control panel, back cover and all inlet/outlet
• Ensure ground is level, fi rm and smooth.
• Replace the failed fi lter motor with a new one.
(263IO) SPA ENGLISH 7.5" X 10.3" PANTONE 295U 08/05/2014
SOLUTION
attached to the control base receptacle.
spa electrical outlet only.
electrical fault.
cover.
twice to heat up the water to the set temperature.
restart all over again.
chemical manufacturer's instructions.
insulated material to bring the pump's connectors
level with the spa's connectors.
During very hot weather, you must check to see
whether it is necessary to release some air. This is
to avoid any possible damage to the tub.
air valve base is tighten, see "Spa Tub Air Valve
Fastening" section.
seams. If there is a leak it will bubble. After you fi nd the leak,
clean and dry the leaking area, then apply the repair patch
that comes with your spa.
ensure inlet/outlet O-ring is in place, clean and not
damaged.
are securely connected.
263
English
A
Page 20

Publicidad

Tabla de contenido
loading

Tabla de contenido