PrOBLeM
Regulator will not shut
off air outlet.
Motor will not run.
CAUSE
Damaged regulator.
Fuse blown, circuit
breaker tripped.
Extension cord is wrong
length or gauge.
Loose electrical
connections.
Faulty motor.
Motor overload protec-
tion switch has tripped
19 - ENG
COrreCTiON
Replace.
Check fuse box
for blown fuse and
replace as necessary.
Reset circuit breaker.
Do not use a fuse or
circuit breaker with
higher rating than
that specified for your
particular branch circuit.
Check for proper fuse.
You should use a time
delay fuse.
Check for low voltage
problem.
Check the extension
cord.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
Check the extension
cord.
Check wiring
connection inside
terminal box.
Have checked by
a Trained Service
Technician.
Refer to Motor
Overload Protection
under Operation.
If motor overload
protection trips
frequently, contact
a Trained Service
Technician.