Descargar Imprimir esta página

Reliable 8000 Serie Manual De Instrucciones página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

WATER LEVEL PROBE CLEANING PROCEDURE
We recommend you clean the water level probe once a month. This cleaning
operation must be carried out ONLY by authorized personnel. Please follow the
cleaning instructions as indicated below:
1. REMOVE THE COVER OF THE LEVEL PROBE
2. REMOVE THE CONNECTION PLUG
3. UNSCREW THE LEVEL PROBE WITH A TUBE SPANNER DIAM. 18MM
4. TAKE OUT THE LEVEL PROBE
SPECIFICATIONS
Power supply: 120V
Total Installed Power 1200W
Pump Power: 60 Hz 1,1.5 mm c f
Boiler Capacity: 4.5 L/1.25 Gal
Ironing Endurance: CONTINUOUS
Operating Steam Pressure: 60 PSI / 4 BAR
Maximum Pressure: 80 PSI / 5.5 BAR
IMPORTANT INFORMATION FOR CORRECT
DISPOSAL OF THE PRODUCT
This product must not be disposed of as urban waste. It must be taken to a special
local waste collection centre or to a dealer providing this service.