ZF PADOVA
ELECTRIC TROLLING VALVE (E.T.V.)
This is an electrical device that has the same functions and is used in the same way as the M.T.V.
The E.T.V. operates via a proportional solenoid valve.
TOWING
Towing can be done continuously for 8 hours. Check that the oil temperature does not go over 80°C.
The position of the control lever is of no importance when the engine is off.
Do not perform any operations on the transmission during towing, as the propeller may start
turning.
CONTROL VALVE SHIFT CONTROL LINKAGE
When installing the shift control linkage,
make sure the travel on the lever takes it
right to the travel limit, when operated from
the bridge console.
If it doesn't, this could result in the burning of
the clutches because the oil flow rate will be
too low.
Plus d'informations sur : www.dbmoteurs.fr
Fig. 6.1
10