Descargar Imprimir esta página

Rockwell Automation Allen-Bradley Stratix 5100 Manual Del Usuario página 206

Punto de acceso inalámbrico/puente de grupo de trabajo

Publicidad

Capítulo 6
Configuración del WAP Stratix 5100 mediante la interface de línea de comandos
206
bridge-group 1 subscriber-loop-control
bridge-group 1 block-unknown-source
no bridge-group 1 source-learning
no bridge-group 1 unicast-flooding
bridge-group 1 spanning-disabled
!
interface Dot11Radio0.40
encapsulation dot1Q 40
no ip route-cache
bridge-group 40
bridge-group 40 subscriber-loop-control
bridge-group 40 block-unknown-source
no bridge-group 40 source-learning
no bridge-group 40 unicast-flooding
bridge-group 40 spanning-disabled
!
ssid wpa_ssid
!
interface GigabitEthernet0
no ip address
no ip route-cache
duplex auto
speed auto
bridge-group 1
no bridge-group 1 source-learning
bridge-group 1 spanning-disabled
!
interface GigabitEthernet0.40
encapsulation dot1Q 40
no ip route-cache
bridge-group 40
no bridge-group 40 source-learning
bridge-group 40 spanning-disabled
!
ip radius source-interface BVI1
radius-server host 10.91.104.92 auth-port 1645
acct-port 1646 key 7 091D1C5A4D5041
!
Si desea obtener instrucciones en Device Manager, consulte
seguridad en la página
Publicación de Rockwell Automation 1783-UM006B-ES-P – Enero 2015