Descargar Imprimir esta página

Eaton Metalux Skybar Instrucciones De Montaje página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions – Skybar Single Sensor Mounting Instructions
3.
Insert the upper tab of the sensor housing into the
alignment embosses in the channel. Side tabs go inside
the channel sides (Figure 2).
Be sure the spherical emboss engages the hole on top
of the channel and all the holes align (Figure 3).
4.
Using the two screws previously removed from the
end plate, secure the sensor housing through the same
holes (Figures 3 & 4).
Figure 2.
Figure 3.
Figure 4.
2
EATON
IB519005EN
Alignment
Emboss
Embosses
Lock
Spherical
Emboss
Installation instructions
Skybar Mid-Row Sensor Mounting Instructions
1.
Remove the two screws attaching the metal end plates
as shown (Figure 1) on the ends of two fixtures on
either side of the sensor. Discard the end plates but
retain the screws for use later.
2.
Connect all wiring to sensor as shown on the sensor
instruction sheet supplied separately.
3.
Insert the upper tabs of the sensor housing into the
alignment embosses in each of the channels. The side
tabs go inside the channel sides (Figure 2).
4.
Push the sensor housing in until the spherical emboss
engages the hole on top of the channel and all the
holes align (Figure 5). Repeat the procedure for the
opposite side fixture.
5.
Using the 4 screws previously removed from the end
plates, secure the sensor housing through the same
holes (Figures 5 & 6) on both fixtures.
6.
Install the additional two screws provided with the
housing through the top of the channel and into the
tabs to further secure the tab into the alignment
embosses (Figure 5).
Figure 5.
Figure 6.