Panduit CT-3001 Manual De Usuario página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
© Panduit Corp. 2014
An incomplete crimp can cause a fire.
Use proper connector and cable combinations. Improper combinations can result in an incomplete crimp.
The relief valve will sound to indicate a completed crimp. If you do not hear the sound of the relief valve, the
crimp is not complete.
Inspect tool before use. A worn or damaged tool may result in breakage striking the operator or nearby
personnel.
Do not perform any service or maintenance other than as described in this manual.
Injury or damage to the tool may result.
Do not operate the tool without dies. Damage to the ram or crimping tool head can result.
Use this tool for the manufacturer's intended purpose only.
Keep the tool head and tool body portion clean and free from debris. Soap and a damp cloth should be used
to clean the tool body.
Always store the tool in its clean, dry carrying case when not in use.
DO NOT press trigger and release button simultaneously. Damage to trigger linkage may result.
Always point tool away from others.
If the tool is kept in cold temperatures below 23
to room temperature for 1 hour before using.
Always verify the proper size connector for the conductor, by checking the color code and the printing on the
connector.
Avoid dropping the tool. Extreme shock may damage the hydraulic circuit and result in malfunction of the tool.
NOTE: CONNECTIONS UTILIZING THIS TOOL ARE U.L. LISTED AND C.S.A. CERTIFIED ONLY
WHEN PANDUIT COPPER COMPRESSION CONNECTORS ARE USED. USE OF ANY
OTHER BRAND OF COMPRESSION CONNECTORS IS NOT RECOMMENDED.
DIE SELECTION
NOTE: DIES ARE DESIGNED TO
PROVIDE THE HIGHEST QUALITY
CRIMPING WHEN USED WITH PANDUIT
COMPRESSION CONNECTORS.
USE OF ANY OTHER BRAND OF
CONNECTORS IS NOT RECOMMENDED
WITH CD-2001 DIES.
MAINTENANCE
It is recommended that the hydraulic fluid be changed every 24 months. The tool should be returned to
Panduit Tool Solutions Division (USA); or Panduit EMEA (EUR) for proper oil changing.
OPERATION MANUAL
WARNING
CAUTION
IMPORTANT INFORMATION
o
Page: 4 of 48
o
F/-5
C for any extended time, it is advisable to return the tool
CT-3001, CT-3001/E
ENGLISH

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ct-3001/e

Tabla de contenido