5.4.2 Exemplary settings
Example 1 is the factory setting (since factory settings are entered by computer, all DIP
switches of a new product are set to 'off').
DS-1 Charge voltage
DS-2 Charge voltage
DS-3 Search mode
Example 1: (factory setting)
1, 2
GEL 14.4 V
3
Search mode off
3 Store setting: off→ on→ off
Store the settings by toggling DIP switch 3 one time.
The LEDs 'charger' and 'alarm' will flash to indicate acceptance of the settings.
6. MAINTENANCE
The Multi does not require specific maintenance. It will suffice to check all connections once
a year. Avoid moisture and oil/soot/vapours, and keep the device clean.
off
DS-1
off
DS-2
off
off
DS-3
off
→
←
→
Example 2
1,2
Gel Victron Long Life
3
Search mode off
3 Store setting: off→ on→ off
17
on
DS-1
DS-2
DS-3
←
Example 3
1, 2
3
3 Store setting: on→ off→ on
on
on
on
→
←
Tubular plate 15V
Search mode on