Astralpool 42350 Smart+ 60 Manual De Instalación Y Mantenimiento página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
5.3. Production level selection
To select the desired production level, press the "
[11] will display the value of the production scale light [4]. The system will set its production to the desired level after a few seconds.
In normal conditions, the production value [4] should be the same as the programmed value. If the salt level in the water is outside the
permitted range ("HIGH SALT" [7] or "LOW SALT" [6] alarms on), or there is a problem in the electrolysis cell ("ELECTRODES" [13] alarm
on), however, the production value [4] could be lower than the programmed and displayed value [11].
WINTER Mode: during periods of low water temperature, where the chlorine demand will be low, select a production level [1] of 50-
60%, because in this way power consumption and lifetime of the package of electrodes are optimized.
5.4. Salinity test
AstralPool Chlore Smart + systems have an integrated system to detect the salinity level of pool water. To run the test, press the "SALT
TEST" [9] key. During the test, the production light will range from 20%-80% of the salinity scale [5], alternately displaying "SALT" and "TEST"
on the system information screen [11]. Once the test is completed, the light will blink for a few seconds on the scale [5] on the detected
salinity value (see Fig. 23). The equipment will return to normal operating mode after a few seconds.
WARNING:
1.
The system might show lower than actual salt levels if the temperature falls beneath 20
2.
Salinity test does not work when the system is stopped by ORP control or flow alarm.
-
+
" [1] / "
" [14] keys until the production level light blinks. The system information screen
Fig. 22
Fig. 23
16
O
C.

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido