EnviroBoss EB100 Manual Del Propietário página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CONTROLS AND OPERATING
INSTRUCTIONS
Set unit upright
NOTICE: Transporting or storing the unit in a
horizontal position is not recommended. When the
machine is placed in a horizontal position, the oil
from the compressor can flow into the
refrigerant coils and reduce the ability of
the dehumidifier to function and possibly
damage the unit. If the unit has been
placed in a horizontal position, set it
upright and let it stand for at least 30
minutes before turning it on.
Positioning a Dehumidifier
For best results, operate your dehumidifiers
in an enclosed area. Close all doors and
windows to maximize water removal
efficiency. Place your dehumidifier away from
obstructions, and keep it away from anything
that could block airflow into and out of the
unit. For more information about creating an
optimum humidity control environment,
contact EnviroBoss at 800-932-3030.
Extend handle
Release the handle by rotating red locking
lever outward, then lift handle up into place.
Rotate red lever back into locked position to
secure handle in operating position.
NOTICE: Do not use the extended handle to
lift the unit off the ground horizontally. Do not
use the extended handle as an attachment
point to strap the unit in a vehicle for
transport. These uses will place undue strain
on the handle attachment points in the
housing.
Set up drain hose
The EB100 condensate pump connects to a
plastic drainage hose. This hose is equipped
with a quick-connect fitting for quick
attachment to the provided drain hose.
Unwrap the entire hose and place the
unattached end in a sink, drain or bucket –
anywhere that water can drain out or be
collected safely. If you use a bucket or other
container for water collection, check it
regularly to prevent overflows.
NOTICE: Uncoil and straighten the entire
drain hose. Do not leave any part of the hose
coiled on the unit and do not place the end of
the hose higher than 20 ft. (6 m) above the
bottom of the unit. Also check for kinks or
other obstructions that might restrict the flow
of water. A kink or blockage will cause the
07-02332C EB100
unit to turn off produce an ER9 error code. See "Error
Messages" below for more information.
Plug in electrical cord
The dehumidifier should be plugged into a GFCI-
protected 115 volt outlet rated for at least 15 amps.
Remove the cord from the storage tray and uncoil it.
FIG A: PARTS IDENTIFICATION
FRONT
Power cord and
drain hose
storage.
Humid air inlet.
Air filter.
Front panel. Remove to
access the pump and
coils for cleaning. See
Fig. B.
REAR
Integrated handle. Use the
red lever to lock handle
upright for use or down
for loading or storage.
Control panel.
Power cord
socket.
Drain hose quick-
connect.
Model serial
number label
Process (dehumidified)
air outlet.
2
EnviroBoss

Publicidad

Tabla de contenido
loading

Tabla de contenido