Relocate Cutting Device From Centre Position To Outer Position - Solo 880-12 Manual De Instrucciones

Ocultar thumbs Ver también para 880-12:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.8

Relocate cutting device from centre position to outer position

The power tool is delivered for operation of the cut-off wheel in the centre position by default. Generally,
the power tool is more balanced in the centre position, because the weight is distributed symmetrically to
the centre axis and the cut therefore is easier to guide.
If obstacles are very close to the cutting location, it may be required to install the cutting device in the outer
position so that the cut-off wheel is located farther towards the outside.
When working with the cut-off wheel in the outer position, observe the asymmetric weight
distribution! If possible, work in the centre position.
Conversion from centre to outer position
b
2
d
30
a
3
c
30
14
e
13
f
g
h
14
3
c
d
b
Preparation
x Put the power tool on level ground.
x Remove the cut-off wheel: Î Chap. 5.3, page 17
x Remove the water supply line (30):
Unscrew the attachment screw (a) of the water
supply line on the right and left sides of the wheel
guard (2).
Remove both adapter pieces (b) including the
line from the wheel guard. Put down adapter
pieces including line so that the line does not
interfere with the following work steps and is not
clamped.
x Remove handle for wheel guard adjustment (3).
Loosen both attachment screws (c) of the handle
a
for wheel guard adjustment and remove the
handle.
x Loosen both attachment nuts (d) of the ribbed
belt cover (14).
x Turn ribbed belt tension screw (13) towards the
left, e.g. counter-clockwise, to reduce the ribbed
belt tension.
Turn until the square nut (e) has been moved
WRZDUGV WKH PDUN í (f) as far as possible. When
installing the cutting device in the centre position
i
(cf. figure), the square nut is all the way to the
left; in case of installation in the outer position, it
is located all the way to the right.
x Remove both attachment nuts (d) entirely.
x Remove the ribbed belt cover (14).
Remove wheel guard (2)
x Carefully move the wheel guard towards the
motor unit. The screws (g) of the assembly
flange (j) are moved within the oblong holes.
x Once the wheel guard has been moved towards
the motor unit until the ribbed belt support (i) can
be pulled through the ribbed belt (h), remove the
wheel guard. Observe that the ribbed belt is not
damaged by this.