P u t t i n g i n t o S e r v i c e
A i r S u p p l y
All tools are operated with compressed air at an optimum pressure of 5.5 bar. We recommend the use of pressure regulators and
filtering systems on the main air supply. These should be fitted within 3 metres of the tool (see diagram below) to ensure maximum
tool life and minimum tool maintenance.
Air supply hoses should have a minimum effective working pressure rating of 150% of the maximum pressure produced in the system
or 10 bar, whichever is the highest. Air hoses should be oil resistant, have an abrasion resistant exterior and should be armoured where
operating conditions may result in hoses being damaged. All air hoses MUST have a minimum bore diameter of 6.4 millimetres or
inch.
7 1 2 2 3 To o l R e m o v a b l e B o t t l e
7 1 2 2 4 To o l F i x e d B o t t l e
A d j u s t i n g t h e Va c u u m E x t r a c t i o n
Using a screwdriver, turn Rotary Valve 38 until the air flow at the rear of the tool ceases.
With the nose of the tool pointing downwards, insert a fastener into the nose and hold it into position.
Turn the rotary valve either way until there is sufficient suction to retain the fastener.
STOP COCK
(USED DURING MAINTENANCE
OF FILTER/REGULATOR OR LUBRICATION UNITS)
3 METRES MAXIMUM
AIR LUBRICATION
PERMISSABLE
STOP COCK
(USED DURING MAINTENANCE
OF FILTER/REGULATOR OR LUBRICATION UNITS)
3 METRES MAXIMUM
8
AIR LUBRICATION
PERMISSABLE
8
PRESSURE REGULATOR
AND FILTER (DRAIN DAILY)
PRESSURE REGULATOR
AND FILTER (DRAIN DAILY)
1
/
4
TAKE OFF POINT
FROM
MAIN SUPPLY
MAIN SUPPLY
DRAIN POINT
TAKE OFF POINT
FROM
MAIN SUPPLY
MAIN SUPPLY
DRAIN POINT
7

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

71223

Tabla de contenido