Troubleshooting - Schumacher Electric XI75DU Manual Del Usuario

Convertidor de energía
Ocultar thumbs Ver también para XI75DU:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

 – The continuous load demand from the device exceeds the converter's
wattage output.
 – The converter is overheated and automatically turns off for a period of 1
to 3 minutes to cool. Make sure the inverter is well ventilated. It will automatically
restart after it cools.
 – The vehicle's battery voltage is less than 10.5 volts.
– Short circuit, power surge or overload in the device.


9. TROUBLESHOOTING

PROBLEM
Alarm is on.
POSSIBLE CAUSE
Display shows . Device has
a short circuit or demands too
much surge power.
Display shows .
12 volt battery is too low.
Display shows voltage in
between 10.5-11.0 volts.
Display shows .
12 volt voltage is too high.
Display shows . Device
demands more than the converter's
continuous power rating.
Display shows . Converter
is too hot.
Cycle the converter power OFF
and ON. If problem persists, use a
larger converter or a smaller device.
Remove the defective device.
Recharge/replace battery.
12 volt battery is low. Recharge/
replace battery. The converter will
automatically shut off after battery
voltage reaches 10.5-volts.
If in a vehicle, repair/replace the
alternator or charging system. Use
a properly sized and rated 12 volt
battery. If the input voltage returns
to 15 volts or less, the converter
will automatically restart.
Cycle the converter power OFF
and ON. If problem persists, use a
larger converter or a smaller device.
Increase the ventilation to the
converter. Move the converter to
a cooler area. Reduce the power
consumption of the device. The
converter will automatically reset
after cooling.
• 9 •
REASON/SOLUTION

Publicidad

Tabla de contenido
loading

Tabla de contenido