Descargar Imprimir esta página

GRAPHITE PRO 59GP004 Manual Del Usuario página 27

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 171
REPLACING THE CARBON BRUSHES
Immediately replace worn out (shorter than 5 mm), burnt or cracked motor carbon brushes. Always replace
both carbon brushes at a time.
● Unscrew and remove carbon brush covers (8) (fig. E).
● Pull the pressure spring away, snap out and remove worn out carbon brushes.
● Remove any carbon dust with compressed air.
● Install new carbon brushes (they should easily slide into the brush holders) and reinstall the pressure
spring (fig. F).
● Fix carbon brush covers (8).
After the carbon brushes are replaced, switch on the grinder with no load and wait for 1-2 minutes
to make the carbon brushes fit the motor commutator. Carbon brushes should be replaced by a
qualified person using original spare parts only.
All types of faults and defects should be eliminated by an authorised service of the manufacturer.
RATED DATA
Power supply voltage
Power supply frequency
Rated power
Rated rotational speed
Max. grinding wheel diameter
Inner disc diameter
Spindle thread
Protection class
Weight
Year of manufacture
NOISE AND VIBRATION DATA
Information regarding noise and vibration
The following levels of emitted noise, such as emitted acoustic pressure Lp
and measurement uncertainty K have been given in the instruction manual as defined in the EN 60745
standard.
The following vibration value (acceleration value) a
as defined in the EN 60745 standard.
The vibration level provided in this instruction manual have been determined according to the measurement
procedure as defined in the EN 60745 standard and can be used for comparison of power tools. This can be
used for preliminary assessment of exposure to vibrations.
The provided vibration level is representative for main applications of the power tool. If the power tool is
used for other applications or with other working tools, and if it is not sufficiently maintained, the vibration
level may vary. The aforementioned reasons may increase the exposure to vibrations during the entire
operating period.
In order to precisely estimate the exposure to vibrations, periods should be accounted for, in which the
power tool is switched off, or when it is switched on, but not operated. Thus, the total exposure to vibration
may prove considerably lower.
Additional safety measures should be taken to protect the user against effects of vibrations, such as:
maintenance of the power tool and its working tools, ensuring proper temperature of the hands and proper
organisation of work.
SPECIFICATIONS
Angle Grinder
Parameter
h
A
and measurement uncertainty K have been determined
27
Value
230 V AC
50 Hz
2400 W
6500 min
-1
230 mm
22,2 mm
M14
II
6 kg
2016
and acoustic power level Lw
A

Publicidad