You should completely de-energize the device before cleaning (washing). Open the door,
loosen the straining pulley and remove the saw blade. Wash the device with hot water. Clean
main assemblies and parts with a wet cloth and hot water. After washing thoroughly wipe
all the parts of the device.
Pay special attention to hard-to-reach places in the device, chain gear pulleys and lower
parts.
Upon removal of bolts from the pulley, all other parts are removed from the left side (and
installed in the same manner). It means that the bolt shall be loosened by turning it clockwise
upon which it is possible to remove all other parts, thereby preventing moisture ingress to
the electric equipment of the device.
Maintenance and care
Upon 200 service hours you should lubricate supports of the straining and driven pulleys.
Upon 5,000 service hours you should remove the straining pulley and spring, replace the
bearing in the pulley support.
Noise emission category
The maximum noise generated by the device is 70 dBA
Scheme
Technical data:
Model
Voltage
Saw blade length
Power
Weight
Gross dimensions
HKN-SE/2020
380V
2020 mm
1500 W
106.00 kg
560x600x1525 mm