Audio Inputs
Eight balanced mic/line connections are available via eight 5.08mm 3-pin pluggable screw terminal
blocks. All plug-in barrier strip connectors should be wired from left to right as follows:
Pin
Function
1
Audio +
2
Audio -
3 Ground (chassis)
Control Outputs
Four relay connections are available to be configured and operate as Control Outputs. The connectors
are a six-way 3.5mm header with mating pluggable screw terminal block with cable restraint.
Pin
Function
1
Relay C, Channel 1 or 3
2 Relay NC, Channel 1 or 3
3 Relay NO, Channel 1 or 3
4
Relay C, Channel 2 or 4
5 Relay NC, Channel 2 or 4
6 Relay NO, Channel 2 or 4
Control Inputs
Nine Control Inputs are available and can be assigned to operate a control input event. Input nine has the
ability to work as a Status In to allow monitoring of multiple VI-8 devices. The Status Out connection can
then be reported as a summary alarm to external monitoring systems.
Pin
Function
1 Ground (shield)
2 Isolated Ground
3
Input 1
4
Input 2
5
Input 3
6
Input 4
Status Monitor Wiring
Pin
Function
1 Ground (shield)
2 Isolated Ground
3
Input 5
4
Input 6
5
Input 7
6
Input 8
Pin
Function
1
Ground (shield)
2
Isolated Ground
3
Status In / Input 9
4
Status Out
5 24V DC (100mA limited)
6
Isolated Ground